Galvin Engineering Flowmatic TZ-FLOWSENC24B Instalación del producto - Página 4

Navegue en línea o descargue pdf Instalación del producto para Accesorios Galvin Engineering Flowmatic TZ-FLOWSENC24B. Galvin Engineering Flowmatic TZ-FLOWSENC24B 10 páginas. Stainless steel retro fit bluetooth face plate 24v ac, suits enw. sensor

Galvin Engineering Flowmatic TZ-FLOWSENC24B Instalación del producto
Product Installation Guidelines
3. Mount new face plate
Apply a thin bead of silicon on the edge of the
-
wall cut out.
Fit the face plate using screws suitable for the
-
fixing method. (Fasteners to be supplied by
installer).
If extension leads are required, please
-
contact Galvin Specialised.
Do not force the faceplate to fit onto wall
or attempt to disassemble components, as
this could result in damage to sensor.
© Galvin Engineering Pty Ltd
Version 2, 8 September 2021, Page 4 of 10
4. Secure wiring with suppressor (not supplied)
Connect electrical interference suppressor (not
supplied) to each cable (1x Transformer, 1x
Solenoid Lead) as shown and ensure they are as
close to the sensor face as possible
All electrical components should be protected
from contact with water or excessive heat and
installed in accordance with local regulations.
Version 1, 8 September 2021, Page 4 of 10