GAM CUOCOJET Manual - Página 5

Navegue en línea o descargue pdf Manual para Cortador GAM CUOCOJET. GAM CUOCOJET 8 páginas. Vegetable-cutting machine

SECTION 2 INSTALLING THE MACHINE

CHARACTERISTICS OF THE SITE OF INSTALLATION

The machine does not require form of anchoring to the work top or floor. Set the machine in the most appropriate manner
at the chosen site of operation. Bear in mind when selecting the location the dimensions of the machine itself and the type
of products to be processed, leaving sufficient space for the operator or one person to move freely around the machine.
All the support feet located under the base must rest on a solid, stable, uniform and properly- levelled surface.
Install close to the machine and in the most convenient position a shunt connection box or terminal board for distribution
of mains power fitted with a suitable socket with current switch/ limiter and, preferably, also fitted with a high-sensibility
thermo-magnetic ground-fault circuit-interrupter.
The installation site must be properly illuminated to facilitate working with the machine. You should avoid setting up the
machine in places that are too dark or where bright or excessive light is likely to disturb you.
Make sure that nothing can fall onto the machine or cause an obstruction over the ventilation slits.
This would cause overheating with consequent risks and danger for the operator and would probably damage the
machine itself.
For the particular type of operation the machine has to perform there must be low levels of dust in the surrounding
environment. The level should not exceed 0.03 g/cu.m (0.0012 oz/cu. m).
Ambient temperature must not exceed the following limits in the conditions given:
Temperature for normal operation:
Minimum 0° C Max + 35°C
Minimum 32° F Max + 95°F
Temperature for storage:
Minimum -15° C Max + 65°C
Minimum -6.8°F Max +149°F
Relative humidity:
Max 80% with ambient temperature of 20°C (68°F)
Relative humidity:
Max 50% with temp. from 20°C to 60°C (68°F to 140° F)
Altitude of site of installation:
Max 1,000 m (305 ft) a.s.l.
For installation above 1,000 m special electrical equipment has to be installed.
415010 en ma 2017-02