Main Combi 30 Eco Elite Manual del usuario e información importante sobre la garantía - Página 9

Navegue en línea o descargue pdf Manual del usuario e información importante sobre la garantía para Caldera Main Combi 30 Eco Elite. Main Combi 30 Eco Elite 12 páginas. Main combi eco range user's guide and important warranty information

Main Combi 30 Eco Elite Manual del usuario e información importante sobre la garantía
Reset
Display
Table of Error Codes
E20
Central Heating NTC Fault
PCB Fault
E28
E50
Hot Water NTC Fault
E110
Safety Thermostat Operated
Water Pressure Switch Not Operated
E119
E133
Interruption Of Gas Supply or Flame Failure
E160
Fan or Fan Wiring Fault
© Baxi Heating UK Ltd 2009
2
1
3
0
4
bar
Then
Fig. 9

6.0 Care of the Boiler

6.1
Cleaning the Outer case
The painted panels should be wiped with a damp cloth and
then dried completely. DO NOT USE ABRASIVE
CLEANING AGENTS.
6.2
Protection & Precaution
1. The boiler incorporates an integral frost protection feature
that will operate in both modes. If the boiler temperature falls
below 5° C, then the boiler will operate until the water
temperature has been raised.
2. If a system frost thermostat has been fitted (your installer
will be able to advise you), then to operate correctly and
protect your system, the gas and electricity must be left on and
the appliance set in the central heating mode.
3. The boiler incorporates an integral pump protection feature
which continually monitors the time since the pump last
operated. To prevent seizure, the pump will operate for
approximately 1 minute if it has not run in the last 24 hours.
6.3
Fault Indication
1. If a fault occurs on the boiler an error code may be shown
on the facia display (Fig. 9).
2. The codes are either two or three digit, preceded by the
letter 'E'. For example, code E133 will be displayed by 'E1'
alternating with '33'. E50 is shown as 'E' then '50'.
3. E20, E28, E50 & E160 indicate faulty components. You
should make a note of the displayed error code and contact
your installer or service engineer.
4. If E110 is displayed overheat of the primary water or flue
system has occurred. Turn the selector switch to the reset
position and hold for at least 5 seconds. If the boiler does not
relight, or the code is displayed regularly contact your installer
or service engineer.
5. E119 is displayed when the primary water pressure is less
than 0.5 bar. After repressurising the system the boiler should
operate. Your installer will be able to advise you about the
method of repressurising. See page 6 for further details.
6. E133 indicates that the gas supply has been interrupted,
ignition has failed or the flame has not been detected. Ensure
that the gas supply has not been turned off, and turn the
selector switch to the reset position and hold for at least 5
seconds. If the boiler does not relight, or the code is displayed
regularly contact your installer or service engineer.
9