Corbin Russwin Access 800 Manual de instrucciones de instalación - Página 17

Navegue en línea o descargue pdf Manual de instrucciones de instalación para Por cerraduras Corbin Russwin Access 800. Corbin Russwin Access 800 17 páginas. Cl33800 tcac2 series cylindrical lockset
También para Corbin Russwin Access 800: Manual de instrucciones de instalación (16 páginas), Instrucciones de programación (16 páginas)

Corbin Russwin Access 800 Manual de instrucciones de instalación
7) ML20800 TCAC2 Hard Wiring Instructions
7.7) M35 Power/Remote Unlocking with M861 Propped Door, Forced Door.
NOTE:
M861 Harnesses are
Illustrated on page 14
Specific connections
are defined on page 15.
784
9VDC
Power Supply
EGND
120 VAC L/N/G
Normally Open
momentary switch
(Remote unlock
- REX option)
NO
C
Red, 2
White, 3
Green, 4
Orange, 5
Blue, 6
Brown, 7
Yellow, 8
C
*NC
DPS Switch
*Wire for switch
contact closure
when door is opened.
Typical locations
shown in Fig. 1
Installation:
1. ElectroLynx™ System Wiring Instructions (refer to Fig. 1 and Fig. 4)
Look for the mating part on ASSA ABLOY doors and frames. Then plug in all
a.
connectors as shown in Fig. 4 during product installation.
b . Hard wire forced/propped, hard power and/or remote unlock (REX) as shown.
2. Non-ElectroLynx™ System Wiring Instructions (refer to Fig. 1 and Fig. 4)
Cut the 8-pin connector off the Power/Remote Unlock harness and hard wire
a.
to non-ElectroLynx™ door harness. Remote power requires three conductors
and remote unlock requires two conductors.
b . Hard wire door harness to power transfer device.
Hard wire forced/propped, hard power and/or remote unlock (REX), as shown.
c.
Door
Outside
Escutcheon
-9 VDC
+9 VDC
Black, 1
Red, 1
Black, 2
White, 3
Green, 4
QC12 Electric Hinge
with 8 and 4-pin connectors,
12 wires and pigtail harness
END OF INSTALLATION INSTRUCTIONS
6 AA batteries MUST be removed from
controller if 784 Power supply is used.
Inside
Escutcheon
Controller
Fig. 4
Power/Remote Unlocking
Forced Door, Propped Door
ElectroLynx Wiring System
ElectroLynx Door Harness
with 8 & 4-pin connectors.
Harness location is
dependent on door type.
16
Remote Power and
REX Connector TB2
Ground Tab
Motor
Connector
TB1
1 2 3 4 5 6 7 8
M35
Power/Remote
Unlocking
Harness
3 2 1
4
Tan
3
Pink
M861 Forced
Door,
Propped Door
Harness
4-pin
connector
REX Input
Connect to
Device