Airetool PATP-9400-P Manual de uso y mantenimiento - Página 3

Navegue en línea o descargue pdf Manual de uso y mantenimiento para Bomba de agua Airetool PATP-9400-P. Airetool PATP-9400-P 20 páginas. Pneumatic powered hydraulic pump

PATP 9400 P Pump Specifications:
Air Requirement for maximum Pressure
Hydraulic Flow
External Relief Valve Adjustment
Sound Pressure Level
Reservoir Capacity
Dimensions:
Over All Length
Height
Width
Weight

INSTALLATION

Vent Plug
See Figure 1. Remove the shipping plug from the vent
port and replace it with the vent/fill gauge cap supplied
with the pump. Tighten the vent/fill gauge cap hand tight
only.
Hydraulic Connection
2. Connect one end of the hose tube assembly to the
pump connections and the other to the tube puller ram.
Connect the pneumatic control tube to the pendant con-
trol or to the Patp ram. The hydraulic connectors are
push-to-connect and the pneumatic control connections
are keyed with threaded retaining ring (Hand TIght Only).
Air Connection
This pump requires 100 psi air at 40 scfm. A regulator
filter lubricator has been installed on the pump to aid in
providing clean lubricated air. and to allow for air pres-
sure adjustment. Attach incoming air supply to 3/4 NPT
port on air valve with thread sealant.
Vent/Fill/Gauge Cap
@ 50 PSI (3.5 bar)
@ 1000 (69bar)
@ 10000 PSI (690 bar) 30 in
1100 10000 PSI
80-85 dBA
2 Gallon
30 inches
29 1/2 Inches
19 3/4 Inches
160 Lbs.
Oil Level
Check the oil level of the pump prior to start-up and add
Enerpac hydraulic oil, if necessary, by removing the vent/
fill gauge cap (See Figure 1). When the gauge needle
points to the end of the green zone the reservoir is full.
CAUTION: Add oil only when all system components are
in the retract position, or the system will contain more oil
than the reservoir can hold.

OPERATION

1. Check oil level of the pump and add oil if necessary.
See Oil Level instructions.
CAUTION: During system operation, the oil level should
never fall below the yellow zone or pump damage may
occur.
2. Make sure that the pump reservoir is vented (Vent/Fill
Gauge Cap is installed.)
CAUTION: Reservoir must be vented whenever pump is
running. Failure to vent the pump will cause cavitation
and pump damage.
3. To start the pump, press the trigger on the PATP ram
or the pendant button if using the HDP, HDQ, or RAV
ram. The ram will advance as long as the button is held
down.
4. Release the button to retract the ram. The motor will
remain on.
5. Press the red OFF button on the pump to stop the pump
motor. With the motor off, both hoses are de-
pressurized.Oil from the retract line will return to tank.
Pressure Adjustment
Pressure is factory preset and should not require adjust-
ment.
3
100 PSI @ 40 SCFM
3
850 in
/min (13.9 1/min)
3
105 in
/min (1.72 1/min)
3
/min (0.5 1/min)
(69-690 bar)
(7.57 Liters)
(762 mm)
(749 mm)
(502 mm)
(72.7 Kilo.)