5.
Hold the charger fi rmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after use, and then keep it.
Regarding electric discharge in case of new batteries, etc.
As the internal chemical substance of new batteries and batteries that have not been used
for an extended period is not activated, the electric discharge might be low when using
them the fi rst and second time. This is a temporary phenomenon, and normal time required
for recharging will be restored by recharging the batteries 2–3 times.
How to make the batteries perform longer.
(1)
Recharge the batteries before they become completely exhausted.
When you feel that the power of the tool becomes weaker, stop using the tool and recharge
its battery. If you continue to use the tool and exhaust the electric current, the battery may
be damaged and its life will become shorter.
(2)
Avoid recharging at high temperatures.
A battery will be hot immediately after use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate, and the battery life will be shortened.
Leave the battery and recharge it after it has cooled for a while.
CAUTION
If the battery is charged while it is heated because it has been left for a long time
○
in a location subject to direct sunlight or because the battery has just been used,
the pilot lamp of the charger lights for 1 second, does not light for 0.5 seconds (off
for 0.5 seconds). In such a case, fi rst let the battery cool, then start charging.
When the pilot lamp fl ickers in red (at 0.2-seconds intervals), check for and take
○
out any foreign objects in the charger's battery connector. If there are no foreign
objects, it is probable that the battery or charger is malfunctioning. Take it to your
authorized Service Center.
Since the built-in micro computer takes about 3 seconds to confi rm that the
○
battery being charged with UC12SL is taken out, wait for a minimum of
3 seconds before reinserting it to continue charging. If the battery is reinserted
within 3 seconds, the battery may not be properly charged.
MAINTENANCE AND INSPECTION
1.
Inspecting the mounting screws
Regularly inspect all mounting screws and ensure that they are properly tightened. Should
any of the screws be loose, retighten them immediately. Failure to do so could result in
serious hazard.
2.
Cleaning of the charger
When the charger is stained, wipe with a soft dry cloth or a cloth moistened with soapy
water. Do not use chloric solvents, gasoline or paint thinner, for they melt plastics.
3.
Store idle charger
When not in use, the charger should be stored in dry, high or locked-up place — out of
reach of children.