MIEN2016/2018/2024/2026 Rack Mount Industrial Ethernet Switch

2. Application Description

2.1. Hardware structure

2.1.1. System structure

The system hardware is mainly composed of the following parts:
The switching network controller uses high-performance ASIC chip
technology to provide Layer 2 wire-speed forwarding of data packets.
The fiber interface adopts an integrated optical transceiver module with
stable performance.
The power supply adopts industrial-grade power supply, with
over-current, over-voltage and EMC protection.
All copper ports and serial ports have EMC protection.

2.1.2. Whole machine structure

The chassis is a 19-inch 1U rack structure, as shown in Figure 2-1, the
whole machine adopts a six-sided fully enclosed structure. Abandon the
traditional flow fan heat dissipation form, reduce the power consumption of the
whole machine, but also improve the stability of the system.
The dimensions are: 482.6*44*210mm.
The front panel indicators are shown in Figure 2-2
Figure 2-2 Schematic diagram of front panel indicators
The indicator description is shown in Table 2-1.
Function
Power
state
System
status
Figure 2-1 Product appearance
LED
LED color
PWR1
Red
RUN
Green
- 3 -
Condition
Status
Power
On
connection
Power is not
Off
connected
System is
Flashing
working fine