Adexa 6G-TRH60 Manual de instrucciones de instalación y funcionamiento - Página 8
Navegue en línea o descargue pdf Manual de instrucciones de instalación y funcionamiento para parrilla Adexa 6G-TRH60. Adexa 6G-TRH60 20 páginas. Gas lava rock grill
Installation
Clearances
NOTE: Only non-combustible materials can be used in close proximity to this appliance.
Left / Right Hand Side
Rear
Bottom
Assembly
NOTE:
◆ This appliance is assembled before delivery except feet.
◆ This appliance is fitted with adjustable feet to enable the appliance to be positioned securely and level.
◆ Check all accessories complete.
◆ IM will be stated that the appliance shall be installed in such a way that side body surfaces are not
accessible in the installed position.
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON.
1.
The Gas LAVA ROCK GRILL do not require an electrical connection, as they function totally on the
gas supply only.
2.
It is essential that the gas supply is correct for the appliance to be installed and that adequate
supply pressure and volume are available. The following checks should therefore be made before
installation:-
a. Gas Type required for the appliance is shown in the rating label. Check that this is correct for the gas
supply the appliance is being installed for gas LAVA ROCK GRILL, The gas conversion is not suited for
gas LAVA ROCK GRILL.
b. Supply Pressure required for this appliance is shown in the 'Gas supply requirements' section of this
manual. Check the gas supply to ensure adequate supply pressure exists.
c. Input Rate of this appliance is stated on the Rating label .The input rate should be checked against the
available gas supply line capacity. Particular note should be taken if the appliance is being added to an
existing installation.
d. The gas supply tubing or hose shall comply with the national requirements in force and shall be
periodically examined and replaced as necessary.
e. Only local national requirements rubber or PVC flexible hose(Nominal core of hose shall be 6.3mm
to12.5mm) could be used for LP gas connection. The length of flexible hose shall not be more than
1.5meters. The flexible hose shall not come into contact with sharp edges.
f. LP Gas Regulator, flexible hose adaptor and rubber gasket shall be matched with local national
requirements, A Manual Isolation Valve must be fitted to the individual appliance supply line. The
regulator should be certificated according to EN16129 latest version. And the hose should be
Certificated according to the latest version EN 16436-1, BSEN ISO3821, BSEN1327 or DIN 1763
g. Nature gas shall be connected with from nature gas supply pipe to nature gas regulator and connection
adaptor to match with local national installation requirements. The nature gas supply line must be at
least the equivalent of ½" (12.7 mm) iron pipe for single units, A Manual Isolation Valve must be fitted
to the individual appliance supply line.
h. The appliance should be connected to the gas supply by means of Flexible hose or metal pipes --either
rigid or flexible-- having an adequate diameter. When joining pipe fittings, never use oakum or Teflon
as their residues could get to the valve and jeopardize its operation. Instead, interpose a seal gasket
suitable for use in gas systems.
Combustible Surface
Not applicable
Not applicable
Not applicable
6
Non Combustible Surface
150mm Min.
150mm Min.
150mm Min.