ISLAND RANGE HOOD INSTALLATION INSTRUCTIONS
WARNING
All electrical work must be done by a qualified electrician or person with technical background
and understanding.
Before beginning installation switch electric power off at central service panel
and lock service panel door so as to prevent power from being switched on accidentally. When
the power disconnecting means cannot be locked, securely fasten a prominent warning device to
the power service panel.
National electrical codes or prevailing local codes and ordinances.
INSTALLING ISLAND RANGE HOOD
1. Remove kitchen ceiling tiles etc. and locate/create ducting hole.
2. Locate wooden beams adjacent to ducting hole.
3. Insert and attach two wooden pieces forming a square frame around the ducting hole
with the already existing beams.
4. With included screws attach the adjustable white metal support to the wooden frame.
5. Attach duct through the support into the ducting hole in the ceiling.
6. Attach the island range hood to the support system with the included screws after
adjusting the support to the required height.
7. Attach duct to the top of the island range hood.
8. Slip stainless steel duct cover over the duct and adjust to the necessary height.
ELECTRICAL GROUNDING INSTRUCTIONS
This appliance is fitted with an electrical junction box with 3 wires, one of which (green/yellow)
serves to ground the appliance. To protect you against electric shock the green-yellow wire must
be connected to the grounding wire in your home electrical system and it must not be cut or
removed under any circumstances. Failure to do so may result in death or injury to persons.
1. Facing the front of the range hood remove the left knockout and the junction box cover
and install the conduit connector in junction box.
2. Run 3 wires; black, white and green, according to the National Electrical Code and local
codes and ordinances in ½" conduit from the service panel to the junction box.
3. Connect black wire from the service panel to black or red wire in the junction box, white-
to-white and green to green-yellow.
4. Check all light bulbs to make sure they are secure in their sockets.
5. Turn power on in service panel.
Do not use extension cord or adapter plug with this appliance. Follow
9