Figure 5
3. Tighten down both sides of the compression bar evenly with the wingnuts until the bar bends upward approximately
1/4 inch in the middle (see figure 5).
4. Re-install the motor housing on top of the filter mounting (see figure 6) base and retighten latches on either side of the
enclosure (see figure 7). On/Off switch should be facing the front of the unit.
5. Attach the power cord to the input connector on the left side of each motor housing and connect to any suitable 110V
outlet (220V model is available to special order) (see figure 8).
6. Check for operation by turning power knob on (see figure 9).
7. Fill out the filter history card(s), one for each type filter, (see figure 10) and place in clear pouch on the front of the
blower unit(s).