Majestic FSUV30 Instrucciones de instalación y uso - Página 7

Navegue en línea o descargue pdf Instrucciones de instalación y uso para Chimenea de interior Majestic FSUV30. Majestic FSUV30 16 páginas.

Window Frame Removal

Refer to Figure 6.
1. Shut off gas. (See Lighting Instructions)
2. Allow the unit to cool if it has been operating.
3. Pull the frame forward.
4. To reinstall window frame follow the above proce-
dure in reverse.
f i r e - p a r t s . c o m
Fig. 6 Window frame removal.

Log Installation

1. Remove window frame. (See "Window Frame" sec-
tion)
2. Remove logs from packaging.
As with all plastic - these are not toys and
should be kept away from children and infants.
Refer to Figure 7.
3. Place rear log (H2 or H6) on rear bracket. Ensure
log is seated properly, leveled and centered to the
unit, so it will not move from side to side and is firmly
positioned on the bracket.
4. Place front log (H1 or H5) behind the front burner on
top of the front log support. Make sure the log is cen-
tered to the burner.
5. Place ember material on top of front burner. Refer to
"Ember Material Placement" section.
6. Place top left log (H3 or H7) onto locator notches.
Ensure log is secure.
7. Place top right log (H4 or H8) onto locator notches.
Ensure log is secure.
10001784

Operating Instructions

FP1589
FSUV20/30 Vent Free Gas Heater

Ember Material Placement

Separate the ember material into small pieces (roughly
1/2" diameter) and place (keep 1/2" space between
ember pieces) onto the grille in front of the front burner.
Do NOT pack down, leave in fluffy, loose condition for
most realistic ember effects. Do not install more embers
on the burner then come with the unit.
Replacement ember material must be purchased
through our dealers.
Application of excess loose material may adversely
affect performance of the heater.
WARNING: All previously applied loose material
must be removed prior to reapplication.

First Firing

Upon completing your gas line connection, a small
amount of air will be in the lines. When first lighting unit
with pilot light, it will take a few minutes to purge this air.
Once the purging is complete, the pilot and burner will
light and operate as indicated in the instruction manual.
Subsequent lightings of the heater will not require such
purging.
Flame impingement on logs may cause
excessive carbon monoxide production and/or
sooting.
If the flame touches the logs, adjust the logs
slightly so that there is no obstruction.
Caution: The logs may be hot.

Odor During Operation

Neither natural gas nor propane gas give off an odor
when burned. The nature of a vent free combustion
system, however, is such that odors may occasionally
be produced during heater operation when impurities
exist in the immediate area. Cleaning solutions, paint,
solvents, cigarette smoke, candles, adhesives, new car-
pet or textiles, etc., all can create fumes. These fumes
may mix with combustion air and can create odor. Such
odors will disappear over time, however, the condition
can be alleviated by opening a window or otherwise
providing additional ventilation to the area.

Flame Adjustment

For units equipped with Hi/Lo valves, flame adjustment
is accomplished by rotating the Hi/Lo adjustment knob
located near the center of the gas control. (Fig. 8)
7