Majestic fireplaces FireStage UV36 Manual de instrucciones de instalación y funcionamiento para el propietario de la vivienda - Página 6
Navegue en línea o descargue pdf Manual de instrucciones de instalación y funcionamiento para el propietario de la vivienda para Chimenea de interior Majestic fireplaces FireStage UV36. Majestic fireplaces FireStage UV36 12 páginas. Vent-free gas firebox
También para Majestic fireplaces FireStage UV36: Folleto y especificaciones (6 páginas), Manual de instrucciones de instalación y funcionamiento para el propietario de la vivienda (12 páginas), Especificaciones (2 páginas)
UV36 Vent-Free Firebox
Combustible Mantel Clearances
Noncombustible
or Void
Standoff
Fig. 3 Combustible mantel clearances.
21���"
14���"
36"
2" Minimum Clearance to
Side Wall or Mantel Leg
36"
Fig. 4 Framing dimensions.
6
Cabinet Installation
8"
6"
24"
1"
20"
12"
Noncombustible
9"
17"
1/2"
T233
clearances
2/04
1/2" Clearance
Not Required at
this Point
14���"
Min.
36���"
T143
framing dimension
11/4/03 djt
3"
12"
21"
9"
Canopy Installation
Installing the Firebox
This list of specific instructions will help you make cer-
tain that every installation operation is done correctly.
Complete the installation steps in the sequence shown.
LOCAL BUILDING CODES SHOULD BE CONSULTED
IN ALL CASES AS TO THE PARTICULAR REQUIRE-
MENTS CONCERNING THE INSTALLATION OF FAC-
TORY BUILT VENT FREE FIREPLACES.
Select the location for the fireplace by taking into con-
sideration the factors previously outlined in the Choos-
ing the Location section of this manual.
Step 1: Framing the Firebox
The entire fireplace can be elevated above the floor
to achieve a raised hearth effect. This can be done by
adding a small platform to achieve the desired height.
This platform must be a continuous surface extending
the full width and depth of the fireplace.
STOP! INSTALL CANOPY AT THIS TIME BY LOOS-
ENING THE SCREWS LOCATED AT THE TOP
FRONT OF THE FIREPLACE. NEXT, SLIDE THE
SLOTTED FLANGE OF THE CANOPY UNDER THE
LOOSENED SCREWS, THEN RETIGHTEN THE
SCREWS TO SECURE THE CANOPY. (Fig. 3)
Step 2: Install the Firebox
Install the firebox into the framed opening by setting
it directly in front of the opening and sliding it into the
proper position.
Hex Head Screws
Canopy
20007446
T233