Adey MagnaCleanse Manual del usuario - Página 6

Navegue en línea o descargue pdf Manual del usuario para Sistemas de filtración de agua Adey MagnaCleanse. Adey MagnaCleanse 8 páginas.
También para Adey MagnaCleanse: Manual del usuario (12 páginas)

Adey MagnaCleanse Manual del usuario
Step-by-step
Continue the VibraClean radiator
9
agitation to dislodge any sludge
deposits until the return hose to the
RapidFlush filter runs clear.
Isolate and clean the RapidFlush filter
10
as required. Using Personal Protective
Equipment i.e. gloves and paper
towels, wipe off any magnetite into a
bucket. Waste should be bagged and
thrown away. When satisfied, open up
the next radiator, turn off the treated
radiator and repeat the process until all
radiators are clean.
Sludge removal tool available at
adeyspares.co.uk.
Set the boiler control to OFF. Attach a
11
drain hose to the MagnaCleanse drain
valve and secure with jubilee clip.
Turn OFF the HTV connector isolation
12
valve 2 on the return pipe to the boiler,
leaving the HTV isolation valve 1 open.
Check jubilee clips are secure
before and during operation.