Majestic fireplaces MO18M Manual de instrucciones de instalación - Página 5

Navegue en línea o descargue pdf Manual de instrucciones de instalación para Chimenea de interior Majestic fireplaces MO18M. Majestic fireplaces MO18M 18 páginas. Majestic burner/hearth and log kits for natural gas use only

Majestic fireplaces MO18M Manual de instrucciones de instalación
2

Getting Started

A. Size of Firebox
See Table 1 in Section 1.B.
B. Negative Pressure
Negative pressure results from the imbalance of air avail-
able for the fireplace to operate properly. Causes for this
imbalance include:
Exhaust fans (kitchen, bath, etc.).
Range hoods.
Combustion air requirements for furnaces, water heaters
and other combustion appliances.
Clothes dryers.
Location of return-air vents to furnace or air
conditioning.
Imbalances of the HVAC air handling system.
Upper level air leaks: recessed lighting, attic hatch
opening, duct leaks.
C. Tools and Supplies Needed
Tools and supplies normally required for installation:
Pliers
Phillips screwdriver
Tape measure
Crescent wrenches
Gas shutoff valve
Non-corrosive leak check solution
/4 in. wrench, 7/16 in. wrench
D. Inspect the Appliance and Components
Remove the contents from the carton. Attached to the
burner are tags identifying the manufacturer name, serial
number, model number (including gas log size), BTU
ratings, gas type, etc.
Review the attached tags before proceeding. Ensure
that all minimum fireplace dimension requirements are
achieved using Table 1 in Section 1.B. Ensure the gas
type provided in the fireplace coincide with the gas type
marked on the tag.
Depth dimension
Front dimension
Rear dimension
20012914 7/05 Rev. 0
CAUTION
Sharp Edges
Wear protective gloves
and safety glasses during
installation.
WARNING
Asphyxiation Risk
This appliance produces carbon monoxide
(CO).
The free opening areas (in square inches)
of the chimney damper as shown in the
tables must be met.
User must make sure damper is locked
open.
The installer is responsible to ensure
proper ventilation of flue gases before
appliance is used.
Fire needs to draft properly for safe
operation.
WARNING
CFM disclaims any responsibility for, and
the warranty will be voided by, the following
actions:
Installation and use of any damaged appliance or
vent system component.
Modification of the appliance or vent system.
Installation other than as instructed by CFM•
Improper positioning of the gas logs or the glass
door.
Installation and/or use of any component part not
approved by CFM.
Any such action may cause a fire hazard.
5