Finishing
Refer to Page 5, Figure 3 for allowable finishing materi-
als and clearances to combustibles.
All joints, top, bottom and sides, where the wall or
decorative facing material meets the firebox surround
must be completely sealed with a noncombustible
material. (Figs. 11-14)
NOTE: Do not install combustible materials on any
of the black fireplace surround.
Hearth Extension
A hearth extension may be used but is not required for
these fireboxes.
A raised hearth extension may be used as shown in
Figure 15.
Standoff
FE107
Fig. 11 Sealing spaces between appliance and finishing
materials.
See mantel drawing for
shelf-to-surround
dimension
Mantel Shelf
Seal with noncombustible
material ONLY
Surround
Top View
"
2 x 4 Stud
Finished Wall
May be sealed with
Fireplace Front
noncombustible material
Fig. 12 Surround flush with finished wall.
20002068
Noncombustible
Caulking/Insulation
2 x 4
Framing
Finishing Material
Finished Wall
Stud
2 x 4
Standoff
Fireplace
Front
Side View
FP568a
UVSRC Series Firebox
Finished Wall
Must be sealed with
noncombustible
material
Noncombustible
Decorative Facing
Surround
Fig. 13 Appliance surround flush with finished wall.
Finished Wall
Noncombustible
Decorative
Facing
Surround
Fig. 14 Facing on firebox flush with finished wall.
Hearth
Brick
Hearth
Extension
Surround
Noncombustible
Hearth Extension
Combustible
Platform
Fig. 15 Side view of firebox with raised hearth extension.
2 x 4 Finished Header
Standoff
FP610a
2 x 4 Finished
Header
Covered Wall
Must be sealed with
noncombustible material
Standoff
FP611a
FP612b
9