Dimensions
Smoke discharge
The discharge system must be for the stove only
(it is not permissible to discharge into flues in
common with other devices).
The smoke discharge takes place through the
8 cm diameter tube placed at the back.
A "T-connector" with a condensation collection
cap should be provided.
The smoke discharge of the stove must be
connected with the outside using a steel or
black tube (resistant up to 450°C) without
obstructions.
The tube must be hermetically sealed.
To make the tubes airtight and for their eventual
insulation, it is necessary to use material
resistant up to at least 300°C (silicone or putty
for high temperatures).
The horizontal sections can be up to 2 m long.
It is possible to have up to three 90° curves.
If the discharge tube does not insert into the
flue, an appropriately fastened vertical section
of at least 1.5 m is necessary (except for obvious
safety contraindications) together with a
windproof termination (Fig.3). The vertical duct
may be inside or outside. If the smoke duct is
outside it must be insulated (Fig.4).
If the smoke duct is inserted in a flue, it must be
certified for solid combustibles and if it is larger
than 150 mm in diameter, modification is
necessary by inserting a tube and sealing the
discharge in relation to the brick parts of the
cover.
It must be possible to inspect all sections of the
smoke duct. If it is a fixed duct, it must have
openings for inspection and cleaning.
The adjacent locale must not be used as a
garage or be a space without ventilation or
air exchange, a storage area for combustible
material or used for an activity that has a fire
hazard.
5
Figure 3. Internal flue installations that must be
carried out in accordance with regulations
Figure 4. External flue installations that must be
carried out in accordance with regulations
According to the UNI 10683/98 standard, the
stove must not be in the same environment as
extractors or type B gas devices and never with
devices that create lower atmospheric pressure.
Minimum1,5 m
Air intake
T-piece cover for
collect condensation
Insulated tube
T-piece cover for
collect condensation
Air intake