Most tension calibrators (such as a Gamma Tension Calibrator) function by clamping off the
string attached to one the end of the calibrator and applying tension to the string located on
the opposite end of the calibrator. The tension measured by the calibrator will then display
the tension being applied to the calibrator by the machine. If the calibrator and tensioner do
not match then you can adjust the tensioner as follows:
(1) Turn the machine off and restart the machine while holding down the Test buttonuntil
count down is complete. 22 lbs should appear on the display. (2) Apply tension to the
calibrator. (3) If the tension reading on the calibrator does not match the tension displayed
on the machine, use the tension indexing buttons to match the display to the calibrator
reading and press the Enter/Clear button (4) Release the tension applied to the calibrator
and 44 lbs should appear on the display. (5) Repeat steps #2-#4 for 44, 66 & 88lbs. (6) After
completing the adjustment at 88lbs the display will show 00 lbs. (7) Restart the machine
without holding any buttons and the calibration adjustment will be complete

CALIBRATION

14
Tension Calibration Procedure
Each stringing machine has been
checked and calibrated at the factory
using accurate load sensing devices
to ensure that the machine pulls at the
correct tension. However, if you sus-
pect that your machine may not be
pulling at the correct tension you can
check the pulling tension with a cali-
brator and make adjustments if needed.