Troubleshooting
No image on display:
● Ensure the display device has been set to the correct input.
● Ensure the HDMI cables used for both the source/transmitter and the receiver/display are properly
connected and are working. Test the HDMI cables directly from a source to display and ensure their
operation.
● Ensure the twisted pair cable has not been damaged and that it has been terminated correctly with
T568B on both ends. A temporary length of twisted pair cable can be used for testing to ensure that the
devices are all compatible and working properly.
● Ensure proper grounding of the power supply.
● Older devices (HDMI 1.2) may have compatibility issues with different settings. It's advised to put a re-
clocking device such as an HDMI splitter inline between the source device and extender.
Color loss or poor picture quality:
● Ensure the HDMI cables used for the source, transmitter, receiver and display are properly connected
and are of good quality. Test the HDMI cables directly from a source to display and ensure their picture
quality.
● Ensure proper grounding of the power supply.
● If the static becomes stronger or picture quality becomes worse when connecting the video connectors,
this may be due to improper grounding.
● Check the grounding and make sure all the components are properly grounded to a common ground.
Improper grounding may cause damage to the receiver.
If your problem persists after following the above troubleshooting steps, please contact your authorized
reseller or Green Audio technical support.