Major tech MT720 Manual de instrucciones - Página 11
Navegue en línea o descargue pdf Manual de instrucciones para Instrumentos de medida Major tech MT720. Major tech MT720 16 páginas. Ac trms clamp meter
7.2. AC Voltage Measurement
1.lnsert the black test lead into the negative COM terminal and the red
test lead into the positive V
2. Set the function switch to the V~ position.
3. Press the MODE/FD key for 1 second to turn on the VFD test.
4. Press the PEAK key to tum on Peak test.
5. Connect the test leads in parallel to the circuit under test.
6. Read the voltage measurement on the LCD display.
7.3. DC Voltage Measurement
1. lnsert the black test lead into the negative COM terminal and the red
test lead into the positive V
2. Set the function switch to the V~ position.
3. Connect the test leads in parallel to the circuit under test.
4. Read the voltage measurement on the LCD display.
7.4. Resistance
1. lnsert the black test lead into the negative COM terminal and the red
test lead into the V
2. Set the function switch to the Ω
3. Touch the test probe tips across the circuit or component under test.
4. Read the resistance on the LCD display.
7.5. Capacitance Measurements
WARNING: To avoid electric shock, discharge the capacitor under
test before measuring.
1. Set the function switch to the CAP position.
2. lnsert the black test lead banana plug into the negative COM jack and
the red test lead banana plug into the V
positive jack.
3. Touch the test probe tips across the part under test. If "OL" appears
in the display, remove and discharge the component.
4. Read the capacitance value in the display.
5. The display will indicate the proper decimal point and value.
Note: For very large values of capacitance measurement it can take
several minutes before the final reading stabilizes.
CAP·TEMP·Hz% Ω terminal.
CAP·TEMP·Hz% Ω terminal.
CAP TEMP Hz% positive terminal.
position.
CAP TEMP Hz% Ω
11