Major tech MT1882 Manual de instrucciones - Página 17

Navegue en línea o descargue pdf Manual de instrucciones para Multímetro Major tech MT1882. Major tech MT1882 20 páginas. 1000v ac/dc trms multimeter

Major tech MT1882 Manual de instrucciones

8.9. FREQUENCY (ELECTRICAL)

Range
10.00~1KHz
Sensitivity: ACmV Range (≥100mV),ACV
Range (≥6% Range), 6000μA/600.0mA/10.00A
Range (≥6% Range), 600.0μA/60.00mA/6.000A (≥60% Range)

8.10. DUTY CYCLE

Range
0.1%~99.9%
Pulse width: >100us, <100ms;
Frequency width: 5Hz – 150 kHz
Sensitivity: <0.5V RMS
Overload protection: 250V DC or 250V AC RMS.

8.11. DIODE TEST

Range
0.3mA typical
Open circuit voltage: MAX. 3.2V DC
Overload protection: 250V DC or 250V AC RMS.

8.12. TEMPERATURE

Range
-200°C ~1300°C
-328°F ~2372 °F
Sensor: Type K Thermocouple
Overload protection: 250V DC or 250V AC RMS.
Note: Accuracy specifications consist of two elements:
• (% reading)- This is the accuracy of the measurement circuit.
• (+ digits)- This is the accuracy of the analog to digital
converter.
Note: Accuracy is stated at 18 to 28°C (65 to 83°F) and less than
75%RH.
Resolution
0.01Hz
±(1.5% reading)
Resolution
0.1%
Resolution
1 mV
Resolution
1 °C
1°F
Accuracy
Accuracy
±1.2% of reading ±2 dgts
Accuracy
±10% of reading ± 5 digits
Accuracy
±(3.0% reading ± 5°C/9°F digits)
(Probe accuracy not included)
17