Before you start...
Yoursafety and the safety of others
is very important.
We have provided many important safety messages
in this manual and on your appliance, Always read
and obey all safety messages,
This is the safety alert symbol. This symb01
alerts you to hazards that can kill or hurt
you and others, Ati safety messageswiii be
preceded by the safety aiert symbol and the word
"DANGER" or "WARNING", These words mean:
You ca_ be killed or seri0usly injured if you don't
f0110winstructi0ns.
AIi safety messages wiii identify the hazard, teii you
how to reducethe chance of injury, and teli you
what can happen if the instructions are not
followed.
Proper installation is your responsibility. Make
sure you have everything for correct installation.
It is the responsibility of the installer to comply
with the installation clearances specified in these
instructions.
Cooktop installed over oven installation: Only
certain specified cooktop and oven models are
approved for cooktop over oven installations.
Cooktops approved for this type of installation
will have an approval label located on the outside
of the burner box. If you do not find this label,
contact your dealer to confirm that cooktop is
approved. The label on the bottom of your
cooktop lists the cooktop and oven combinations
that are approved for this type of installation.
Ovens approved for this type of installation will
have an approval label located on top of oven. If
you do not find this label, contact dealer to
confirm that oven is approved. Refer to oven
manufacturer's
Installation Instructions for
approval for built-under use and proper cutout
dimensions.
When installing cooktop over a built-under
oven, Do Not fasten cooktop to countertop with
clamps. Cooktop then will be easy to remove if
servicing is ever necessary.
Check location where cooktop will be installed.
The location should be away from strong draft
areas, such as windows, doors and strong
heating vents or fans. The cooktop should be
located for convenient use in the kitchen.
Grounded electrical supply is required. See
"Electrical requirements," Panel B.
Important:
Observe all governing
codes and ordinances.
Failure to meet governing
codes and
ordinances
could lead to fire or electrical
shock.
When installing a cooktop under existing
cabinets and the installation does not meet the
minimum cabinet clearances. Install a range
hood above the cooktop to avoid burn hazards.
Countertop
opening dimensions that are
shown must be used. Given dimensions are
minimum clearances and provide required 0"
(0 cm) clearance.
New installations
-- follow minimum
dimensions given.
Replacement
installations
-- Be sure that
front edge of cooktop is at least 1-1/2"
(3.8 cm) back from front edge of countertop.
It is the customer's
responsibility:
To contact
a qualified
electrical
installer.
To assure that the electrical
installation
is
adequate
and in conformance
with National
Electrical
Code, ANSI/NFPA 70 -- latest
edition**,
or CSA Standards
C22.1-94, Canadian
Electrical
Code, Part 1
and C22.2 No. 0-M91 - latest edition
*** and all
local codes and ordinances.
Product dimensions
30" (76.2 cm) or
_36"
(91.4 cm) width
21" (63.3 cm) depth
15" (38.1 cm)
30" (76.2 cm) or
(91.4 cm) width
2-7/8" (7.3 cm)
burner
box
height
both sides
21-5/16" (54.1 cm) depth
2-3/4" (7.3 cm)
burner
box
height
Cutout
dimensions/requirements
18" (46.7 cm) min.
clearance upper
cabinet to countertop
within minimum
clearances
to cooktop
\,
\
Do not seal
cooktop to
countertop.
Note: 24" (61 cm) rain.
clearance
if bottom
of wood or
metal cabinet
is protected
by
not less than t14" (0.6 cm)
flame retardant mHIboard
covered
with not less than No.
28 MSG sheet steel, 0.015"
(0.04 cm} stainless
steel, or
0.024"(0.00
cm) aluminum
or
0.020" (0.05 cm} copper.
30" (70.2 cm) rain. clearance
between
top of cooking
platform
and bottom
of
unprotected
wood or metal
cabinet.
Junction box,
12" (30,5 cm)
['_
or more above
LJ
floor
and 10"
(25.4 cm) from
right side of
cabinet.
1" (2.5 cm) rain. distance
to
nearest
left and right side
combustible
surface
above
cooktop.
(5.1 cm)
Cooktop
width
A
B
15"
14-1/2"
15"
(38.1 cm)
(36.6 cm)
(38.1 cm)
30"
29-1/2"
30"
(76.2 cm)
(75 cm)
(76.2 cm)
36"
35-1/2"
36"
(91.4 cm)
(90.2 cm)
(91.4 cm)
36" (91.4 cm) or 30" (76.2 cm) min. base
cabinet is required. If cabinet has a drawer, a
3" (7.5 cm) depth clearance from the countertop
to the top of the drawer (or other obstruction) in
the base cabinet is required.
Tools needed for installation:
Copies of the standards listed may be obtained from:
** National
Fire Protection Association
Batterymarch
Park
Quincy, Massachusetts
02269
*** Canadian
Standard
Association
178 Rexdale Boulevard
Etobicoke, (Toronto),
Ontario
Mgw 1R3
Panel A