CenturionPro DBT 3 Manual del usuario - Página 14

Navegue en línea o descargue pdf Manual del usuario para Equipamiento industrial CenturionPro DBT 3. CenturionPro DBT 3 16 páginas. With variable speed control

CenturionPro DBT 3 Manual del usuario
TUMBLER DOES NOT ROTATE UNDER MANUAL FORCE
1) Tumbler and Blade sheet are excessively dirty. Clean Tumbler and Blade Sheet; excessive plant material builts up on these surfaces and causes excess friction.
2) Tension on Blade Sheet is too tight. Reduce tension on Blade Sheet by releasing the pawl and rotating the tension knob in a counter clockwise direction until
the Tumbler can easily be rotated under manual force and the Blade Sheet is in contact with the Tumbler.
ELECTRIC MOTORS WILL NOT START OR HAVE LOW POWER
1) No electric power from the outlet. Plug trimmer into a functional electrical outlet.
2) Outlet is overloaded. Check that breaker is not overloaded and has not tripped. If tripped, switch plug to a different circuit.
3) Extension cord is faulty. Check extension cord is rated appropriately for the distance and current. Do NOT use a longer cord unless the wire size is larger.
Undersized extension cords may cause an under-voltage, over-current condition which could damage or destroy the drive motor and void the motor warranty.
4) Overcurrent circuit has been exceeded. Determine cause of excessive circuit resistance which may include: overloaded outlet, faulty extension cord, bad outlet,
underrated generator, excessively dirty machine, incorrectly tensioned Blade Sheet or obstruction between Tumbler and another part of machine. Once source
of resistance has been identified and resolved, reset circuit by pressing small button on control panel for 3 seconds then operate machine normally.
THE CIRCUIT BREAKER KEEPS TRIPPING.
1) This is caused by a cord that is too long or undersized. Your cord must be no more than 25ft long and the same gauge of thickness as the main cord.
2) Also, ensure the machine is not sharing a circuit with other devices and the correct size breaker is present. Circuit sharing can significantly decrease the power
being supplied to the devices therefore causing the breaker to trip.
3) Test your electrical current to make sure it is producing consistent power. We recommend having a certified electrician set up the proper power supply. This
will ensure your power source is supplying the correct electricity. If you have not done this, have a certified electrician come and test your electrical current to
ensure it complies with the electrical requirements.
MY TUMBLER IS NOT SPINNING.
1) If its not spinning, check for obstructions between Tumbler and Blade Sheet.
2) Ensure that the Tumbler is fully on the drive shaft with the drive pins engaging on the Tumbler plate.
THE PRODUCT IS NOT COMING OUT TRIMMED.
1) Tumbler and/or Blade Sheet are excessively dirty. Clean Tumbler and Blade Sheet.
2) Make sure that the Blade Sheet is tightened onto the Tumbler.
3) Check plant to make sure that moisture content is between 8-10% and that the leaves are snappy and dry, not bendy and pliable.
MY SIDE DRIVE IS HOT.
1) Your machine may be overworking due to a voltage drop in your power supply. This can happen if you're using an extension cord that is too long or undersized. You can
only use an extension cord with a maximum length of 25ft.
2) Use a voltage tester to test your electrical current to ensure you have the correct voltage. We recommend having a certified electrician come in and make sure
your power supply is consistent.
3) Having a motor on for an extended period can be the reason for overheating. Allow the motor to cool down by turning the machine off for an hour, every 5 hours of use.
MACHINE MAKES A LOUD SCRAPING OR CLICKING SOUND.
1) Tumbler and/or Blade Dheet are excessively dirty. Clean Tumbler and Blade Sheet.
2) Tumbler and/or Blade Sheet are Damaged and need to be replaced.
14