Gantner Q Series Manual - Página 14

Navegue en línea o descargue pdf Manual para Unidad de control Gantner Q Series. Gantner Q Series 17 páginas.

Channel
GIns__VariableName
Label
Q.series
Gantner Instruments
5.
Add the number of ARINC words by clicking the OutputVariables
/
buttons.
6.
For each ARINC word the following parameters must be set.
Specify the channel for receiving data from your ARINC device.
IMPORTANT
When using the AIM ASC429-12, channels 1 - 4 are allocated for
transmitting data and channels 5 - 12 are for receiving data. The
GInsARINCPlugin currently support Rx channels only.
Name of the Q.station's virtual variable to write the ARINC word to. For
more information about creating virtual variables, please refer to your
Q.station manual.
The label is used to identify an ARINC 429 word on the data bus. Each label
must be unique, although labels do not need to be listed in a consecutive
order in GI.monitor. The label must be represented as a three octal digits
number (for example 273).
14