IKEA LUFTIG HW400 Manual de instalación y uso - Página 5

Navegue en línea o descargue pdf Manual de instalación y uso para Placa IKEA LUFTIG HW400. IKEA LUFTIG HW400 8 páginas. Range hood
También para IKEA LUFTIG HW400: Manual (16 páginas), Manual del usuario (16 páginas), Manual del usuario (16 páginas)

IKEA LUFTIG HW400 Manual de instalación y uso
61833050a.fm Page 5 Tuesday, February 21, 2006 7:53 PM
INSTALLATION AS AN EXTRACTOR OR FILTER HOOD
Important: the figures are on the first pages of this booklet.
• Fix the bracket on the rear of the hood near the coupling ring (Fig. 1.1a).
Note: the bracket can be adjusted horizontally, which enables the position of the hood to be adjusted (Fig. 1.1b).
• Trace a centre line on the wall between the hob and ceiling (Fig. 2.2).
Mark the distance from the hob (respecting the minimum distance) with the pencil and position the template (if provided)
against the wall on the mark (Fig. 2.3).
Then mark and drill the hole, insert the wall plug and partially tighten 1 screw (Fig. 2.4).
• Fix the flue support as close as possible to the ceiling (Fig. 3.1). For filter operation, in this phase, also fix the deflector
(Fig. 3.2).
Hang the hood on the partially tightened screw (Fig. 3.3a - if necessary, adjust the hood horizontally by means of the
bracket - Fig- 3.3b)
Mark the hood fixing points:
2 at the bottom: remove the grease filters (Fig. 3.4), 2 at the top on the sides of the bracket.
Remove the hood, drill the holes, insert the plugs into the holes (Fig. 3.5), refit the hood, insert and tighten all the screws
(Fig.3.6 - Fig. 3.7)
External Exhaust Mode: Fumes are extracted and expelled to the outside through a fume hose fixed to the collar at the top
of the hood.
Caution! If the hood is equipped with a carbon filter, this must be removed.
Exhaust air must not be conveyed through a flue used for removal of fumes produced by gas combustion appliances or other
combustible materials, but must have an independent outlet. All national regulations governing extraction of fumes must be
observed.
Filter Hood: Air is filtered through a carbon filter and returned to the room.
Caution! If the hood is not already equipped with a carbon filter, one must be ordered and fitted prior to use.
Installing the telescopic flue
• Connect the hood to the mains supply and fix the telescopic flue to the flue bracket with two screws. Slide the bottom
section down into its seat on the top of the hood (Fig. 4).
5019 618 33050/A
GB