IKEA MATMASSIG 503.688.40 Manual - Página 9
Navegue en línea o descargue pdf Manual para Placa IKEA MATMASSIG 503.688.40. IKEA MATMASSIG 503.688.40 24 páginas.
ENGLISH
590 mm
490 ±1
mm
min.
55 mm
max.
R 5 mm
min.
28 mm
Important!
• For further information on the installation
refer to the Assembly Instruction.
• If there is no oven beneath the hob insert
a dividing panel at a minimum distance
of 20 mm from the bottom of the hob.
Electrical connection
Warning! Refer to Safety
chapters.
Warning! All electrical
connections must be made by an
authorised installer.
Electrical connection
• Before connecting, check if the nominal
voltage of the appliance, provided on
the rating plate, corresponds to the
available supply voltage. The rating
plate is located on the lower casing of
the hob.
• Follow the connection diagram (it is
located on the underneath surface of the
casing of the hob).
• Use only original spare parts provided
by spare parts service.
min.
520 mm
500 mm
560 ±1
mm
min. 50 mm
• Do not use silicon sealant between the
appliance and the worktop.
• The appliance is not provided with a
mains cable. Buy the right one from a
specialized dealer. Single phase or two-
phase connection requires a mains cable
of minimum 70°C temperature stability.
Cable needs mandatory end sleeves.
According to IEC regulations use for one-
phase connection: mains cable 3 x 4mm²
and for two-phase connection: mains
cable 4 x 2.5mm². Please respect specific
national regulations in the first priority.
• You must have the means for
disconnection incorporated in the fixed
wiring.
• You must have the connection and the
connecting links carried out as shown in
the connection diagram.
• The earth lead is connected to terminal
and must be longer than leads carrying
electric current.
9
min.
28 mm