Waste water filtration unit AS 300 S
Attention
The pump may not be operated without water.
Before the initial operation of the waste water pump or after a long period of stagnation,
check that the shaft rotates freely when turned by hand. To this put a screwdriver in the
notch of the shaft end on the fan side and move the shaft. In winter the unit may only be
operated in a frost-protected area.
 Fill waste water pump fully through vent connection
 Connect waste water hose
 Make connection between „Sewage" and Sewer
 Establish power supply 230V
 Fill 1/3 of settling tank with water
 Switch on unit (Position „MAN" at selector switch) and check, if water is pumped out
of settling tank
 Turn selector switch to „Auto"
The unit is now ready for operation.