IKEA IH3302WQ0 Manual de uso y mantenimiento - Página 7

Navegue en línea o descargue pdf Manual de uso y mantenimiento para Campana de ventilación IKEA IH3302WQ0. IKEA IH3302WQ0 24 páginas. 30" (76.2 cm) and 36" (91.4 cm) range hood installation instructions

INSTALLATION INSTRUCTIONS
_':_"_cs7 _',_ _}C<X_ Oil'S
NOTE: For vented installations, it is recommended
that the vent
system be installed before hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
1. For vented installations, determine which venting method to
use: roof or wall.
2. Select a flat surface for assembling the range hood. Place
covering over that surface.
/
'll
7 1/2"
,
2" (5.1 cm)
(19 cm)
j
from wall,
not cabinet
frame
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
3. Using 2 or more people, lift the range hood onto covered
surface.
4. If cabinet has recessed bottom, add wood filler strips on each
side. Install screws to attach filler strips in locations shown.
Wood filler strips
(recessed cabinet
bottoms only)
y0om, j
\
3" (7.6 cm)
Wall
Determine
Wiring Hole Location
Cut only one 1V4" (3.2 cm) diameter wiring access hole. See Step
2 for wiring hole location instructions.
Either wiring hole can be
used.
1. Determine and clearly mark a vertical centerline on the wall
and cabinet in the area the vent opening will be made.
A. Centerline
2.
To wire through
top:
Mark a line 71/2 '' (19.0 cm) from the right of the centerline on
the underside of the cabinet. Mark the point on this line that is
2" (5.0 cm) from back wall. Drill a 11¼ '' (3.0 cm) diameter hole
through the cabinet at this point.
I
Centeriine
To wire through rear wall:
Mark a line 71/2 '' (19.0 cm) from the right of the centerline on
the wall. Mark the point on this line that is 34" (1.9 cm) from
underside of cabinet. Drill a 11¼ '' (3.0 cm) diameter hole
through wall at this point.
Ii
_,_
_
3/4' (1.9 cm)
i
i 71/2"
i
' (19cm)
i
i
Centerline
Style 1 - Cut Openings for 31/4 '' x 10" (8.3 cm x 25.4 cm)
Rectangular Vent System
Roof Venting
To make a 4" x 101/2 '' (10.2 cm x 26.7 cm) rectangular
cutout
on the underside of cabinet top and bottom:
1. Mark lines 11/2"(3.8 cm) and 51/2"(14.0 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 51¼"(13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
4. Repeat steps 1-3 for the underside of the tc ) of the cabinet
*From wall, not cabinet frame