Walkthrough Metal Detector with Single Wrist Thermal Sensor 2MTHWT-HMD
1. Password modification
(1) Input the correct password or "1111" and press "ENT" to show Fig. 14, then press "SEL" to enter the password
modification menu, see Fig. 26.
(2) Press "SEL" to select password digits. The digit can be changed by pressing "ADJ" until the 4-digit password is set,
see Fig. 33. The password will be modified successfully after "ENT" is pressed (The password is not saved in the
system though modified successfully, save the set new password according to the "III 4 Save set parameter ").
(3) After the password is modified, see Fig. 34, the password input interface still exists (being equivalent to Fig. 5), the
user can enter the setting menu after the correct password (modified) is input.
2. Sensitivity setting
Input the correct customized password or "1111" and press "ENT" to show Fig. 14. Press "ENT" to enter the parameter set-
ting menu, see Fig. 15.
(1) Press "SEL" to select the submenu (L001~ L008). L001~ L006 refer to the sensitivity of zone l ~ 6. Taking L001
as an example, see Fig. 41 ~ 44, press "ADJ" to select the sensitivity digits. The selected digit can be changed by
pressing "ENT". After the sensitivity of zone 1 is set, press "SEL" to enter the sensitivity setting menu of zone 2.
(2) The sensitivity from zone 1 to 6 can be set separately or set as the same one for the sake of convenience. L007
refers to all sensitivity values from zone 1 to 6, which can be set as the same one by specifying L007 as an non
zero value, e.g. when L007 is set as 150, then the sensitivity from zone 1 to 6 can be Level 150 after the setting is
saved. If it is unnecessary to set the sensitivity as the same one, L007 must be set as 000.
(3) L008 refers to the multiple of the integral sensitivity. The "Once" or "50 times" can be selected. The switching
between "Once" and "50 times" can be enabled by pressing "ADJ". The "ENT" is unnecessary here. If "Once" is
selected, the sensitivity will not change; If "50 times" is selected, the sensitivity will be reduced by 50 times.
Note: The adjustable levels with regard to sensitivity are restricted within Level 0 ~ 999. The higher the value is,
the higher the sensitivity will become; The higher the multiple of is, the lower the sensitivity will become.
3. Alarm setting
Input the correct password or" 1111" and press "ENT" to show Fig. 14, then press "SEL" to enter the alarm setting menu,
see Fig. 15. Press "SEL" continuously to enter the ring tone setting menu (see Fig. 24 or Fig.45), the last two digits of
the lower row digital tube are shown, where the first one the ring tone (9 ring tones i.e. Ring Tone 1 ~ 9 are optional),
the second digit means the volume (Volume 0 ~ 8 are optional, Volume 0 means mute). The "ADJ"and "ENT" are used
for selecting digits and changing selected digit.