Commission instruction
Step 1, press D button to enter below:
Password input
Step 2, press B to shift and C to adjust to enter the password 1318, press D button to enter below:
Power Select Adjust Confirm
Remark:
1) "345" means the starting value of normal temperature voice broadcast is 34.5 ° C.
2) "370" means the alarm temperature is 37 ° C .
3) The default alarm value by factory is 37 ° C.
Step 3, after setting the temperatures, press D to back.
Step 4, press D button, then press B to shift and C to adjust to enter the password 1319, press D button to enter
below:
Power Select Adjust Confirm
Remark:
1) The default environment temperature value by factory is 25 ° C. It's applicable in most situation and no need to
adjust. If necessary, it can be adjust. If we decrease it by 10° C, the body temperature will decrease 1° C. If we
increase it by 10° C, the body temperature will increase 0.5° C.
Step 5, after setting the ambient temperature, press D button for 3 seconds to back
Power Select Adjust Confirm
Power Select Adjust Confirm
Power Select Adjust Confirm
Body Temperature Measurement – Quick Guide V 6.1
Temperature compensation
settings
Alarm temperature setting
Power Select Adjust Confirm
Ambient temperature
compensation settings
Power Select Adjust Confirm