Warranty
Please Note: 1. All installations must be carried out by, and signed off by a PIRB accredited installer.
failure to do so will render the warranty null and void.
2. All installations must comply with SANS 10254.
3. This GAP warranty applies to the GAP Eco Electric, Eco Green & Eco Solar geyser only, all other
components supplied by, and forming part of the system, but not manufactured by GAP carry their own
warranty provided by their respective manufacturers.
Warranty:
The GAP geyser comes with a comprehensive one (1) year parts and labour warranty and guarantee to replace the
GAP geyser if the inner tank of the geyser fails within three (3) years of installation. The element and thermostat carries
a one (1) year warranty.
3 Year Replacement Guarantee:
GAP will provide a free replacement geyser from it's nearest branch or approved agent. The transport, installation and
labour costs of delivering the replacement geyser and removing the existing geyser and installing the replacement geyser,
will be for the account of the owner of the existing geyser.
Where a GAP geyser or a component of the geyser is replaced, the balance of any original warranty or replacement
guaranty period will remain effective. The replacement GAP geyser or part does not carry any additional warranty
or replacement guarantee.
The period of warranty is from date of installation, providing the documented proof of installation and sale is furnished, or
alternatively, from date of manufacture, as determined from the serial plate code on the geyser.
The following conditions apply:
1. The warranty only applies to defects, which have arisen solely due to faulty materials or workmanship during the
manufacturing process of the GAP geyser.
1.1 NB.: The Geyser must not be removed from the installation prior to warranty approval, any removal or
tampering will render the warranty void.
2. The warranty does not cover:-
2.1 Element burnt out through commissioning without water.
2.2 Burnouts due to loose electrical connections.
2.3 Fair wear and tear.
2.4 Misuse, abuse or negligent use of the GAP geyser.
2.5 Any attempt to self repair the geyser, tampering or defacing the serial plate.
2.6 Excessive pressure:- where the incorrect pressure control valve is used, or if the pressure control valve fails. This
geyser requires a 400Kpa pressure valve.
2.7 Where a non GAP approved solar collector or heat pump is connected to the geyser.
2.8 Electrical geyser not installed in roof or under cover.
3. The GAP geyser is fitted with a sacrificial anode (type is area specific), which protects the glass lined water tank.
Replacement of the anode should be carried out at the appropriate intervals, determined by the water quality in the
area, which can be obtained from the water authorities.
The following water specifications and servicing requirements are detailed below.
Total dissolved solids (Parts per million)
100 - 600
601 - 1000
over 1000
NB.: Failure of timeous replacement may result in permanent damage to the geyser and voiding of
warranty.
In the event of maintenance the following clearance should be provided for unobstructed access.
• 300mm clearance around the safety valve.
• 450mm clearance around the front electrical cover plate.
Recommended anode replacement
3 years
2 years
1 year
NB.: ● Geyser installation must comply with SANS 10254
● The 400 kPa T/P valve must be installed before commissioning or use.
● This product is rated for 400 kPa and must be installed with the correct
pressure control valve.
Maintenance
1. Switch off Geyser at the DB board and the Isolator switch before commencing with any maintenance.
2. Thermostat:
• Thermostat is located under electrical cover, disconnect wiring from thermostat.
• Remove thermostat from thermostat pocket.
• Replace thermostat with the same type of thermostat.
• Reconnect wiring to thermostat.
• Set temperature. GAP recommends 55ºC.
3. Element:
• Using the drain cock, drain the geyser. We recommend removing one vacuum breaker for this process.
• Element is located under the electrical cover, disconnect wiring from element.
• Unscrew element and replace with a new element and gasket. Element must be of equal energy value.
• Close the drain cock and replace the vacuum breaker. Refill with water and check for leaks.
• Reconnect the wiring to the element.
4. Anode:
• Drain the geyser using the same process as element replacement.
• Anode is located under the Anode cover below the T/P valve port.
• Unscrew anode from geyser.
• Replace with the correct new anode and gasket. Obtainable from GAP geyser distributers.
• Refill the geyser with water in the same process as element replacement.
5. System Failure:
NB.: In the event of geyser or pipe failure follow the directions below.
• Switch off the electricity at the DB board.
• Switch off the water supply to the geyser, normally located near the geyser.
• Using a container, try to limit any potential damage to the property.
• Contact GAP Holdings warranty department on +27 11 974-0131 or [email protected]
Doc. No.: Gm-004
Rev.: 04-19/11/2018