Avantco UDD1 Manual del usuario - Página 7

Navegue en línea o descargue pdf Manual del usuario para Electrodomésticos de cocina Avantco UDD1. Avantco UDD1 17 páginas.

Avantco UDD1 Manual del usuario
Drain Instructions
On direct draws, the drain is located at the front of the cabinet .
(UDD1 & UDD1S drain into a bottle located inside the unit)
To plumb in the drain, connect ½" PVC pipe to the barbed fitting supplied with the unit .
If you would prefer to drain the beer inside the unit (for mobility or where a drain can't be found):
- Use a screwdriver to remove the drain bracket .
- Pull the drain hose so that it is inside the unit .
- Attach a bottle to the drain hose inside the unit .
- Plug the created hole at the bottom of the unit

Startup

- Temperature control set at No . 4 position gives refrigerators an approximate temperature of 35°F .
Allow unit to function several hours, completely cooling cabinet before changing the
control setting .
- Excessive tampering with the control could lead to service difficulties . Should it ever become
necessary to replace temperature control, be sure it is ordered from your Avantco dealer or
recommended service agent .
- Good air flow in your unit is critical . Be careful to load product so that it neither presses against
the back wall, nor comes within four inches of the evaporator housing . Refrigerated air off the coil
must circulate down the back wall .
Recommendation:
Before loading product, we recommend you run your Avantco unit empty for 2-3 days . This allows
you to be sure the electrical wiring and installation are correct and no shipping damage has
occurred . Remember, the Avantco factory warranty does not cover product loss!

Temperature Setting

Dial Controls (UDD1 & UDD1S ONLY)
Temperature range from (7) Coldest to (1) Warmest
Digital Controls (All Other Models)
Refrigerators are programmed to operate between 33 and 40°F
To set the temperature you would like your unit to run at:
1 . Hold "SET" for 1 sec . The display will flash the temperature
that the refrigerator is currently set to .
2 . Use the arrow buttons to adjust the temperature .
3 . Press "SET" to save your settings .
If the unit consistently runs 5+ degrees higher than your set
temperature, service may be needed .
Note: All other control functions should only be performed
by a trained service technician.
User Manual
- 7 -
Dial Controls
Digital Controls
set