GAPOSA QC100 Manual de instrucciones - Página 15

Navegue en línea o descargue pdf Manual de instrucciones para Unidad de control GAPOSA QC100. GAPOSA QC100 16 páginas. Single-phase control unit

GAPOSA QC100 Manual de instrucciones
ALERTS
The following table shows the various light signals generated by the
control unit with their meaning and possible operations to be performed.
CONTROL UNIT STATUS
READY FOR COMMANDS
EXECUTION
WAITING FOR AUTOMATIC
CLOSING
MOTOR UPWARDS
MOTOR DOWNWARDS
PAUSE TIME PROGRAMMING
WORKING TIME
PROGRAMMING
RESET IN PROGRESS
RED LED
1 FLASH
2 FLASHES
8 FLASHES
LED SWITCHES ON STEADILY
CONTROL UNIT FEEDBACK
GREEN LED
ON
SHORT SHUTDOWN EVERY
3 SECONDS
SLOW FLASHING WITH
DUTY CYCLE 50%
FAST FLASHING WITH
DUTY CYCLE 50%
SHORT FLASHING EVERY
SECOND
ON
3 CLOSE FLASHINGS
EVERY 3 SECONDS

TROUBLESHOOTING

ERROR SOLVING
CHECK THE STOP BUTTON CONNECTIONS
CHECK THE SAFETY DEVICES CONNECTIONS / CHECK SAFETY
ACTIVATION
CHECK:
• POWER SUPPLY
• OVERLOAD OUTPUT 12V (TERMINALS 9-3)
• OVERLOAD OUTPUT 24Vac (TERMINALS 11-12)
WRONG DIPS SETTING, FOLLOW THE BELOW PROCEDURE:
1. SET ALL DIPS IN OFF POSITION
2. WAIT FOR 5 SECONDS
3. SET THE DIPS IN THE DESIRED POSITION FOLLOWING THE
INSTRUCTIONS
RED LED SOLUTION
OFF
-
OFF
-
OFF
-
OFF
-
OFF
SEE PROCEDURE 5.1
ON
SEE PROCEDURE 5.3
OFF
PUT DIP 5 AND 6 IN OFF