5 .1

Mounting Cabinets with up to 432 Fibers on a Wall

Step 1:
For standard installation
on a wall, secure a
4-foot by 8-foot by 1/2-
inch sheet of plywood to
the studs of the wall in
the mounting location,
with the top of the
plywood approximately
80 inches above the
floor (Figure 5) at the
height specified in
your standard local
procedures.
Step 2:
Using appropriate
hardware (not
provided), attach the
mounting bracket to the
plywood approximately
75 inches above
the floor. Ensure the
bracket is level and
secured to the wall to
support the weight of
the cabinet.
Step 3:
Attach the wall-mount
brackets to the rear of
the cabinet as shown in
Figure 5.
Step 4:
Using the hoist or lifting
device, lift the cabinet
and hook the mounting
bracket over the bracket on the wall (Figure 6).
IMPORTANT: Lower edge of the cabinet or splice chamber should be approximately 36 inches above
the floor.
Step 5:
Screw the bottom bracket into the plywood and move the lifting eyes to their stored
position (Figure 6).
Step 6:
If desired, remove and reinstall the lifting eyes in their stored position.
5 .2

Mounting Cabinets with up to 432 Fibers into a Rack

Use the rack-mount kit (P/N 07-033330-001) to secure a cabinet with up to 432 fibers to a
23-inch rack. Follow instructions provided with the kit.
5 .3

Mounting Cabinets with more than 432 Fibers to the Floor

Use a forklift or handtruck to move the frame-mounted cabinet into position in the lineup. Secure
the frame to the floor using your company's approved procedures.
STANDARD RECOMMENDED PROCEDURE 003-873 | ISSUE 2 | APRIl 2016 | PAGE 6 OF 18
Wall Studs
80 inches
Plywood
Floor
KPA-1783
36 inches
Floor
1
Attach plywood to wall.
2
Attach mounting bracket to plywood.
3
Attach mounting brackets to cabinet.
Figure 5 — Install Mounting Brackets
Figure 6 — Mount Cabinet on the Wall
KPA-0057