CORNING ONE RAU5x Hoja de instalación rápida - Página 6

Navegue en línea o descargue pdf Hoja de instalación rápida para Instrumentos de medida CORNING ONE RAU5x. CORNING ONE RAU5x 8 páginas. Five-band remote access unit

9.
FOR CONFIGURATIONS WITH
GEM - CONNECTIONS
Step 1:
Connect DC wire pair to the RAU5x
SECONDARY POWER DC input connector
(see Figure 7):
• Wire size: 12-30 AWG
• Maximum consumption:
Connectez la paire de fils DC au RAU5x
connecteur SECONDARY POWER
(voir Figure 7):
• Taille de fil: 12-30 AWG
• Consommation électrique maximale:
- GEM: 4 W
- Pour deux PoE ports of 802.3af: 46 V;
- Pour deux PoE ports of 802.3at: 52.5 V;
Step 2:
Fiber connections - connect fiber to SFP
module ports as follows:
Step 3:
Connect the A and B Ethernet ports to the PoE
clients using Ethernet cables.
Note:
A and B Ethernet ports – 10/100/1000BASE-T
with 802.3 at compliant Power-over-Ethernet
(PoE+) PSE port.
Corning Optical Communications
- GEM: 4 W
- For 2 PoE ports of 802.3af: 46 V; 31 W
(Input range: 43-57 VDC)
- For 2 PoE ports of 802.3at: 52.5 V; 62 W
(Input range: 52-57 VDC)
31 W (plage d'entrée: 43-57 VDC)
62 W (plage d'entrée: 52-57 VDC)
- If using fiber terminated with LC APC
(green) – connect to pre-inserted APC to
UPC adapters
- If using fiber terminated with LC UPC
connector (blue) – remove pre-inserted
APC to UPC adapters and connect
directly to SFP module ports
Figure 7. RAU5x MAIN and SECONDARY DC Input
Connections
Figure 8. GEM Interface Connections
Quick Installation Sheet | CMA-485-AEN | Page 6