Garden GP04 Manual de instalación y uso - Página 14

Navegue en línea o descargue pdf Manual de instalación y uso para Bomba de agua Garden GP04. Garden GP04 16 páginas. Swimming pool heat pump

Garden GP04 Manual de instalación y uso
IX. Maintenance
A."Cut off" power supply of the heater before any examination and repair;
B. In winter season when you don't swim:
a)
Cut off power supply to prevent any machine damage
b)
Drain water clear of the machine.
c)
Cover the Heat Pump to avoid dirt entering
C.Please clean this Heat Pump with household detergents or clean water,
NEVER with gasoline, thinners, or any similar petrol products;
D.Check bolts, cables and connections regularly.
!!Important:
Unscrew the water nozzle of inlet pipe to
let the water flow out.
When the water in machine freezes in
winter season, the titanium heat exchanger
may be damaged.