Empire DVLXG55B Manual del propietario - Página 2

Navegue en línea o descargue pdf Manual del propietario para Chimenea de interior Empire DVLXG55B. Empire DVLXG55B 14 páginas. Direct vent zero clearance gas fireplace heater

If you do not follow these instructions exactly, a fire or explosion may result, causing property damage,
personal injury, or loss of life.
A. This appliance must be lighted with the remote
control. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING, smell around the
appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than air and
will settle on the floor.
What to do if you smell gas:
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbours phone. Follow the gas supplier's
instructions.
If you can not reach your gas supplier, call
the fire department.
1. STOP! Read the safety information above.
2. Turn OFF electric power to the appliance.
3. Ensure that the gas shut-off valve is in the
"ON" position.
4. Wait ten minutes. Then smell for gas, including
near the floor. If you smell gas, STOP! Follow "B"
in the safety information above on this page. If
you do not smell gas, go to the next step.
5. Turn ON electric power to the appliance.
Flame Sensor
1. Turn off all electrical power to the appliance if
service is to be performed (if applicable).
2. Turn gas shut off valve to "OFF" position.
2

INTERMITTENT PILOT LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

LIGHTING INSTRUCTIONS
Electrode
Pilot

TO TURN OFF GAS TO FIREPLACE

WARNING
C. Use only the remote control to operate the
valve. Never use tools. If the valve does not
operate, don't try to repair it; call a qualified
service technician. Force or attempted repair
may result in fire or explosion.
D. Do not use this appliance if any part has
been underwater. Immediately call a qualified
service technician to inspect the appliance and
to replace any part of the control system and
any gas control which has been underwater.
6. Use the remote to turn your fire on. If the
pilot does not light within 60 seconds, stop and
go back to step 5.
7. If the burner or pilot does not operate
properly after several tries, turn the gas shut-
off valve to the "OFF" position and call your
service technician or gas supplier.
8. Operation of the fire is controlled by a man-
ual on/off switch or a hand held remote control.
Refer to remote instructions for detailed
operation information.
OFF
SHUT-OFF VALVE
ON