Jandy AquaPure Ei Series Instrucciones - Página 3
Navegue en línea o descargue pdf Instrucciones para Sistemas de filtración de agua Jandy AquaPure Ei Series. Jandy AquaPure Ei Series 4 páginas. Replacement kits for models apure35plg / 35plgc
También para Jandy AquaPure Ei Series: Manual (8 páginas)
4. Power Pack Wiring Instructions
WARNING
When using electrical products, basic precautions
should always be followed, including the following:
• DANGER: RISK OF ELECTRIC SHOCK WHICH
CAN RESULT IN SERIOUS INJURY OR DEATH.
Before attempting installation or service, ensure
that all power to the device is disconnected/turned
off at the circuit breaker. Connect only to a circuit
protected by a ground-fault circuit-interrupter
(GFCI).
• Grounding is required. The unit should be
serviced by a qualified service representative and
should be properly grounded and bonded.
• Install to permit access for servicing.
• Please read all cautions and safety instructions
in the Important Safety Instructions section of
the Jandy AquaPure
(H0335900 or H0342400). Before attempting
any electrical wiring, be sure to read and
follow safety instructions. Wiring should only
be attempted by a qualified professional.
A. Connection to an AquaLink
Control System or PDA (Optional)
The Jandy AquaLink RS or PDA is a multi-function
pool controller which can fully control the function
of the Jandy AquaPure Ei chlorine generating device.
Adjustment of the chlorine production rate can be
controlled from the main menu of the Jandy AquaLink
RS or PDA. The AquaLink RS or PDA offers individual
pool and spa settings for output percentage. Refer to
the AquaLink RS or PDA Owner's Manual for more
information.
NOTE The Jandy AquaPure Ei chlorine generating
device will communicate with all AquaLink
models Rev. K or later.
B. Verify the Controller Type on the Power
Pack is Set Correctly
Before wiring to an AquaLink RS Control System,
the controller type must be set to JANDY L/M to
allow communication between the power pack and the
AquaLink RS Control System. The default controller
type setting on the power pack is Jandy L/M. Follow
the instructions below to verify the controller type is set
correctly.
NOTE The controller type must be set correctly before
making the wiring connection between the
power pack and the AquaLink, otherwise the
power pack may be locked out of the AquaLink.
Ei
Series owners manual
®
TM
RS
®
To verify the controller type is set correctly:
1. Apply power to the power pack.
2. Wait for the start-up sequence to complete.
3. Press and hold the OUTPUT button for
approximately four (4) seconds. After four (4)
seconds, a controller type will be displayed on the
screen.
4. Verify that the JANDY L/M controller type appears
on the display. If the contoller type is not set to
JANDY L/M, keep the OUTPUT button pressed to
toggle through the list of contollers. Each controller
will be displayed on the screen for two (2) seconds.
Release the OUTPUT button when JANDY L/M
appears on the display.
C. Wiring to the AquaLink RS Control
System or PDA
1. Ensure that all power to the power pack and the
controller is disconnected/turned off at the circuit
breaker.
2. Remove the screws attaching the cover to the back
plate and prop the cover up to expose the terminals
(see Figure 6).
NOTE: Be careful not to pull the ribbon cable that is
connected to the Power Supply and the Cover.
Comm Hole
Figure 6.
Accessing and Wiring to the Power PCB
Page 3
Cable Tie