9.5 Motor Replacement

1.
Have a qualified service technician or electrician
properly disconnect the electrical wiring at the
pump motor.
2.
Follow steps 1-7 of section 9.2, "Removing the
Impeller."
3.
Remove the four (4) bolts holding the mounting
bracket to the motor. Before removing the
bracket, note the alignment of the mounting
bracket to the motor (See Fig. 3).
4.
Replace the motor with an identical make and
model.
5.
Replace the four (4) bolts holding the mounting
bracket to the motor.
6.
Follow steps 1 thru 15 of section 9.3, "Replacing
the Impeller."
7.
Have a qualified service technician or electrician
properly connect the electrical wiring at the
pump motor.
Note: It is recommended that the mechanical seals be
replaced at the same time the motor is replaced.
Figure 8. Mounting Bracket Assembly
Mounting Bracket
Bolts & Washers (4)
Motor
Page 13