Empire Comfort Systems AV42MTEKN-1 Instrucciones de instalación y manual del usuario - Página 8

Navegue en línea o descargue pdf Instrucciones de instalación y manual del usuario para Chimenea de interior Empire Comfort Systems AV42MTEKN-1. Empire Comfort Systems AV42MTEKN-1 20 páginas. Triple burner

Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment
or accessories and repair and servicing of equipment shall be per-
formed only by a qualified agency. The term "qualified agency" means
any individual, firm, corporation or company which either in person
or through a representative is engaged in and is responsible for (a)
the installation or replacement of gas piping or (b) the connection,
installation, repair or servicing of equipment, who is experienced in
such work, familiar with all precautions required and has complied
with all the requirements of the authority having jurisdiction.
State of Massachusetts: The installation must be made
by a licensed plumber or gas fitter in the Commonwealth of
Massachusetts.
The installation and the provisions for combustion and ventilation
air must conform with the National Fuel Gas Code, ANSI Z223.1/
NFPA54* Canadian Installation Code CAN/CGA B149.
*Available from the American National Standards Institute, Inc. 11
West 42nd St., New York, N.Y. 10018.
Gas inlet pressure
Gas
Model
Type
AV36
NAT
Manual
AV42
NAT
Manual
Note:
Thermostats are for vent-Free Applications only.
Page 8

GENERAL INFORMATION

PRODUCT SPECIFICATIONS

Natural
Gas
Max.
10.5"
Min.
7.0"
Valve
BTUH
Orifice
Type
Max. Rate
19
120,000
12
140,000
High Altitude Installation
When installing this unit at an elevation above 2000 feet (in the
United States) it may be necessary to decrease the input rating by
changing the existing burner orifice to a smaller size. Generally,
input should be reduced 4 percent for each 1000 feet above sea
level. However, if the heating value of the gas has been reduced,
this general rule may not apply. Check with local gas utility for proper
orifice size identification.
For Canadian high altitude applications, this appliance is suitable for
installation at elevations between 0 feet (0m) and 4,500 (1,370m)
without change.
When installing this unit at an elevation above 4500 feet (1,370m)
(in Canada), check with local authorities.
Consult your local gas utility for assistance in determining the proper
orifice for location.
MINIMUM FIREPLACE DIMENSIONS
MASONRY BUILT FIREPLACES
Chimney Height Minimum of 6 Feet
FRONT
LOG SET
DEPTH IN
WIDTH IN
SIZE
INCHES*
36"
42
42"
48
MINIMUM FIREPLACE DIMENSIONS
FACTORY BUILT FIREPLACES
Chimney Height Minimum of 10 Feet
FRONT
LOG SET
DEPTH IN
WIDTH IN
SIZE
INCHES*
36"
24
42"
30
Note: Natural gas match throw sets may be used in some areas.
Check your local codes for this configuration.
WARNING
DO NOT use sand in Liquid Propane Hearth Kits. Use the
Rockwool mix, provided with the Liquid Propane Change Kit.
MINIMUM
HEIGHT IN
INCHES
INCHES
INCHES
18
18
18
18
MINIMUM
HEIGHT IN
INCHES
INCHES
INCHES
18
18
18
18
35651-0-0615
VENT
IN SQ.
71
71
VENT
IN SQ.
71
71