Turn power supply off.
Electrical Shock Hazard
Do Not use two wire with a bare
grounding wire. All current-carrying
wires
must be insulated.
Failure to follow these instructions could
result in fire, electrical shock or death•
U-shard
hook
•
I
Figure
8
Figure
9
Direct wire preporolion
2.
Strip outer covering back 3 inches (7.6 cm)
from end exposing the wires. (See Figure 8.)
Strip the insulation back 1 inch (2.5 cm) from
the end of each wire, Form the bare wire into a
"U" shaped hook, (See Figure 9.)
brass
terminal
terminal
block
cover
Figure 10
3.
Remove the terminal block cover located on
)ack of range. Remove the 3/8" (0,95 cm) brass
terminal nuts attached to the knockout.
Do Not
remove
knockou L-_
_
J
conduit
connector
opening
Figure
11
4.
Attach a U.L.-listed conduit connector to
the opening, Do Not remove the knockout.
Place power supply cable through conduit
connector, allowing enough slack to easily
attach the wiring to the terminal block. (See
Figures 11 and 12.)
si,v. ,ored ,/I
terminal
/ !
block screw _iL
groundi
link
_
onduit
Figure 12
5,
Using the 3/8" (0.95 cm) brass nuts, attach
the neutral (white) of power supply cable to the
silver-colored center screw of the terminal
block. Place the hook-shaped end of the wire
over the terminal block screw with open side of
the hook facing to the right. Squeeze hook end
of wire together to form a loop.
Connect the other two wires to the outer
terminal block screws. Attach wires using the
same method as the neutral wire. (See Figure
12.)
Do Not loosen the factory-installed
nuts on the
terminal block,
Center wire MUST be connected to center
screw,
6.
Tighten conduit connector, locking ring and
clamping screws.
7 • Reattach terminal block cover.
Panel C
Mobile home or other four-wire
installations:
Electrical Shock/Fire Hazard
Check that wiring you are using matches
colors shown in illustrations and specified
in instruction steps. If wiring does Not
match, it is your responsibility to have a
qualified electrician install the correct
wiring.
Failure to follow these instructions could
result in fire, electrical shock or death.
4
/
•
Turn power supply off.
brass
terminal
i/terminal
block
cover
Figure 13
i.
Remove the terminal block cover located on
back of range. Remove the 3/8" (0.95 cm) brass
terminal nuts attached to the knockout.
Remove knockout
,pening for
Figure
3.
Remove the knockout for the 40-ampere
power supply cord.
4,
Attach a 3/4" (1.9 cm) U.L.-listed strain
relief (U.L marking on strain relief) to the
opening. Tighten strain relief firmly to cabinet.
Place power supply cord through strain relief.
link screw
Figure
15
5,
Remove the grounding-link screw from the
range frame. Save the grounding-link screw,
Bend up the grounding link so that it does not
contact the range.
silver-
,_ IIH/
\\/l
\\_l
l
colored
I/
terminal
_.
block
screw
Green
wire
insulated
\\
_re
MUST
connected
before
connecting
neutral
- (white)
_.,U.L. listed
Figure
16
strain relief
6.
Connect the green grounding wire to the
range using the grounding-link screw removed
in Step 5. The green grounding wire must be
attached first and must Not contact any other
terminal.
7.
Using the 318" (0.95 cm) brass nuts,
attach the neutral (white) wire of power supply
cord to the center, silver-colored screw of the
terminal block.
Connect the other two wires to the outer
terminal block screws. (See Figure 16.)
Do Not loosen the factory-installed
nuts on the
terminal block.
Be sure the wiring nuts are installed tight.
8.
Tighten strain relief screws.
9o Reattach terminal block cover.
1,
Turn power supply off.
J_(7"3"cm---'_)
U-shaped
hook
Figure
17
Figure
Direct wire preparation
2.
Strip outer covering back 3 inches (7.6 cm)
from end exposing the wires. (See Figure 17.)
Strip the insulation back 1 inch (2.5 cm) from
the end of each wire. Form the bare wire into a
"U" shaped hook. (See Figure 18,)
_'_
.. terminal
block
brass
_
cover
terminal
Figure
19
3,
Remove the terminal block cover located on
back of range. Remove the 3/8" (0.95 cm) brass
terminal nuts attached to the knockout.
J
Do Not
/
conduit
remove
connector
I_ockout_
Figure 20
U.L listed
COnduit
r
4,
Attach a U.L.-listed conduit connector to the
opening. Do Not remove the knockout. Place
power supply cable through conduit connector,
allowing enough slack to easily attach the wiring
to the terminal block. (See Figures 20 and 21 .)
Figure
22
5,
Remove the grounding-link screw from the
range frame. Save the grounding-link
screw.
Bend up the grounding link so that it does not
contact the range.
silver-
colored -
terminal
block
screw
Green
insulated wire
MUST be
Connected
before
connecting
other wires.
,(white)
wire
', U.L. listed conduit
connector
Figure
23
6,
Connect the green grounding wire to the
range using the grounding-link
screw removed
in Step 5. The green grounding wire must be
attached first and must Not contact any other
terminal.