Gardena 3000/4 Manual de instrucciones - Página 8

Navegue en línea o descargue pdf Manual de instrucciones para Bomba de agua Gardena 3000/4. Gardena 3000/4 15 páginas. Pressure tank unit
También para Gardena 3000/4: Manual del usuario (10 páginas), Manual de instrucciones (14 páginas), Manual de instrucciones (10 páginas), Manual de instrucciones (7 páginas), Manual del usuario (9 páginas), Manual del usuario (10 páginas), Manual de instrucciones (13 páginas)

Gardena 3000/4 Manual de instrucciones

8. Available accessories

GARDENA Suction Hoses
GARDENA Suction Hose Fitting For connection on the suction side.
GARDENA Pump Connection
Set
GARDENA Suction Filter with
backflow preventer
GARDENA Pump Preliminary
Filter
GARDENA Electronic
Manometric Switch
GARDENA Dry-Running
Safety
GARDENA Bore Hole Suction
Hose

9. Technical Data

Type
Rated power
Max. delivery capacity
Max. pressure / max. delivery head 3.6 bar / 36 m
Max. self-priming suction height
Perm. internal pressure
(delivery side)
Voltage / Frequency
Connection cable
Weight
Noise level L
1)
WA
1)
Measuring method according to directive 2000/14/EC
Kink-proof and vacuum-proof, optionally available by the metre
Art. no. 1720/1721 (19 mm (3/4")- / 25 mm (1")) without connecting
fittings or in fixed length Art. no. 1411/1418 complete with con-
necting fittings.
For connection on the delivery side.
To equip suction hoses with backflow
preventer sold by the metre.
Recommended for pumping
sandy liquids.
Automatically cuts in and out the pump
depending on the current operating
pressure. With dry-running safety. It must
be installed at one of the two outlets.
Prevents the pump from damages in
case of missing liquid.
The Dry-Running Safety cannot be directly
connected to the pump and must be
mounted with Original GARDENA System
Fittings in the pressure hose.
For vacuum-resistant connection of
the pump to boreholes or pipe networks.
Length 0.5 m. With 33.3 mm (G1) female
thread at both ends.
3000/4 (Art. no. 1707)
600 W
3,100 l/h
7 m
6 bar
220 – 240 V AC / 50 Hz
1.5 m; H07-RNF
6.5 kg
measured 78 dB (A)
guaranteed 81 dB (A)
Art. no. 1723/1724
Art. no. 1750/1752
Art. no.
1726/1727/1728
Art. no. 1730/1731
Art. no. 1739
Art. no. 1741
Art. no. 1729
3500/4 (Art. no. 1709)
800 W
3,600 l/h
4.1 bar / 41 m
7 m
6 bar
220 – 240 V AC / 50 Hz
1.5 m; H07-RNF
7.0 kg
measured 82 dB (A)
guaranteed 85 dB (A)
17