2.1 Overview
Display of:
– Total delivery capacity
– Partial delivery capacity
– Turn on pressure
– Leakage warning
– Diagnosis system
– Pump temperature
2.2 Reset
Reset of:
- Partial delivery capacity to 0
- Min./max. Pump temperature
2.3 Main menu
Leads back to the main menu.
3. Settings
The "Settings" menu has 5 submenus:
3.1 Leakage warning
3.2 Turn on pressure
3.3 Troubleshooting
3.4 Factory settings
3.3 Main menu
v Select the desired menu with the left
3.1 Leakage warning
To set the duration until the leakage
warning is activated:
– ON (60 min)
– ON (2 min)
– OFF
v Select the desired duration with the left
3.2 Turn on pressure
The turn-on pressure is set to the maximum value at the factory and can
be reduced to 2.0 bar in 0.2 bar steps.
To set the turn-on pressure:
v Select the desired turn-on pressure with the left or right button and
confirm it with the centre button.
3.3 Troubleshooting
To activate troubleshooting.
– ON:
Shows the most frequent causes and their remedy on the
display.
– OFF: Only the error code is shown on the display.
v Select the desired setting with the left or right button and confirm it
with the centre button.
3.4 Factory settings
Reset to the factory settings of:
– Leakage warning to 60 min.
– Turn on pressure to maximum value
– Troubleshooting to ON
3.5 Main menu
Leads back to the main menu.
4. Exit
Closes the main menu.
The pump is ready for operation again.
5. MAINTENANCE
DANGER! Electric shock!
Risk of injury due to electric current.
v Disconnect the product from the mains before you maintain
the product.
or right button and call it up with the
centre button.
or right button and confirm it with the
centre button.
To clean the filter [ Fig. M1 / M2 ]:
1. If applicable, close all the shutoff devices on the intake side.
2. Loosen the lid
(9)
of the filter chamber with the spanner
3. Remove the filter unit
(12)
/
(13)
vertically upwards.
(12)
4. Hold the cup
firmly, turn the filter
remove the filter 2 (bayonet fitting).
5. Clean the cup
(12)
under running water and clean the filter
e. g. with a soft brush.
6. Assemble the filter again in reverse order.
7. Start the pump (see 3. OPERATION).
To clean the check valve [ Fig. M3 ]:
CAUTION!
The pump must not be operated without the check valve.
1. If applicable, close all the shut-off devices on the intake side.
2. Open all tapping points so that the pressure escapes on the pressure
side. Now close the tapping points again so that the connected pipes
do not drain via the pump.
(14)
3. Loosen the cover
of the check valve with a suitable tool.
(15)
4. Remove the check valve
and clean it under running water.
5. Assemble the check valve
(15)
6. Start the pump (see 3. OPERATION).
6. STORAGE
To put into storage [ Fig. S1 ]:
The product must be stored away from children.
(11)
to position 0.
1. Push the on / off switch
2. Disconnect the pump from the mains.
3. Open the consumer on the pressure side.
4. Remove the connected hoses on the pressure and suction side.
5. Unscrew drain bolt
(1)
.
6. Tilt the pump to the suction and pressure side until water is no longer
discharged from either side.
7. Store the pump in a dry, enclosed and frost-free place.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household waste.
It must be disposed of in line with local environmental regulations.
IMPORTANT!
v Dispose of the product through or via your municipal recycling
collection centre.
7. TROUBLESHOOTING
DANGER! Electric shock!
Risk of injury due to electric current.
v Disconnect the product from the mains before you
troubleshoot the product.
To troubleshoot with the error diagnosis system:
The pump is equipped with an error diagnosis system which indicates the
cause and the remedy of various error states via the display.
1. Push the right button
The display shows the first possible error.
2. Disconnect the pump from the mains (the error display is retained).
3. Make the indicated remedy (or the respective remedy from the table
below).
4. Start the pump again.
5. If the error is not fixed, go back to step 1 and call up the next possible
error.
6. When the error is fixed, push the right button (Reset).
The pump is ready for operation again.
(A)
provided.
(13)
counterclockwise 1 and
(13)
again in reverse order.
.