for yoUr sAfEty
If you smell gas
• T urn off gas supply at source.
• E xtinguish all naked flames.
• D o not operate any electrical appliances.
• V entilate the area.
• C heck for leaks as detailed in this manual.
If odour persists, contact your dealer or gas supplier
immediately .
Do not tamper with the appliance.
Burn-back (fire in burner tube
or chamber)
In the event of a burn-back, where the flame burns
back to the jet, immediately turn off the gas supply
at the control valve on the panel . after ensuring the
flame is extinguished, wait for 1 minute and re-light the
appliance in the normal manner . should the appliance
again burn back, close the control valve and call a
service technician . Do not use the appliance again until
the service technician has declared that it is safe to
do so .
Gas-pressure regulator
this appliance requires an operating pressure of 2 .8
kpa at the appliance . a suitable lpG regulator that
complies with the requirements of saNs 1237 must
be installed .
Important information for the user
this appliance may only be installed by a registered
lp Gas installer. all registered installers are issued
with a card carrying their registration number . ask to
be shown the card before allowing the installation
work to commence and make a note of the Installer
qcc number . upon completion of the installation, the
installer is required to explain the operational details of
the appliance together with the safety instructions . you
will be asked to sign acceptance of the installation and
be provided with a completion certificate . you should
only sign for acceptance of the installation when the
installation is completed to your satisfaction .
Note that your invoice is required in the event that you
wish to make a guarantee claim.
Important information for the installer
this appliance may only be installed by a lp gas
installer registered with the liquefied petroleum Gas
association of southern africa . the appliance must be
installed in accordance with the requirements of saNs
10087-1 and any fire department regulations and / or
local bylaws applicable to the area . If in doubt check
with the relevant authority before undertaking the
installation . upon completion of the installation you are
required to fully explain and demonstrate to the user
the operational details and safety practices applicable
to the appliance and the installation .