Aliyiqi ADT-1000A Manual - Página 10
Navegue en línea o descargue pdf Manual para Equipos de prueba Aliyiqi ADT-1000A. Aliyiqi ADT-1000A 12 páginas. Horizontal torsion spring testing machine
1. Under normal circumstances, plug in the power cord, turn on the power switch,
and after the display is stable, if the display data is not zero, please press the\"\"
Zero\"\" key to clear and clear the torque value.
2. According to the test needs, press the moment unit conversion key to select
the required unit.
3. Set up before the test, the specific steps such as parameter setting interface.
Twelve, torsion spring torque test procedure
1. According to the test requirements, select the appropriate mandrel and install
the mandrel to the mounting holes of the test heads on both sides.
Then install the spring under test on the main test mandrel, one end of which is
fixed by the secondary mandrel.
2. Shake the handle to make the third mandrel contact with the other end of the
torsion spring, and the force value and angle will be cleared at the same time just
after contact.
3. The torque value and angle value displayed on the LCD screen are zero.
4. According to the torsion spring measurement requirements, rotate the
measuring handle smoothly and evenly to display the technical parameters of the
torsion spring being tested.
5. Repeat the above operation to verify the technical parameters of the torsion
spring.