Garmin 190-01166-02 Manual de instrucciones de instalación - Página 16

Navegue en línea o descargue pdf Manual de instrucciones de instalación para Equipamiento marino Garmin 190-01166-02. Garmin 190-01166-02 48 páginas. Marine autopilot system

Garmin 190-01166-02 Manual de instrucciones de instalación
Hydraulic Considerations – Legacy 2.1 L Pump
Different boats have different hydraulic considerations you must examine before mounting the pump or disconnecting any hoses.
Before starting the hydraulic installation, verify the type of hydraulic steering in your boat, and where to install the appropriate type of
pump.
If the hydraulic steering of your boat does not match the hydraulic layouts in this manual, contact Garmin Product Support.
Legacy 2.1 L Pump Hydraulic Layout on Single-Helm Boats
Shadow Drive
S
R
P
Helm
Port fitting
Do not turn the system on until you bleed all the air from the helm, the Shadow Drive, the pump, and all the hydraulic lines.
See
page
34.
1
Starboard line
Return line
Port line
Legacy .1 L
pump (and motor)
Starboard fitting
Balanced cylinder
Notice
notes:
Legacy 2.1 L pump (and motor):
Do not use the legacy 2.1 L pump on a system
with an unbalanced cylinder.
Mount the pump horizontally if possible. Do not
mount the pump vertically with the pump end
(hydraulic connections) down.
Shadow Drive:
Mount the Shadow Drive horizontally and as
level as possible.
Install the Shadow Drive in either the port or the
starboard hydraulic line.
Always install a length of hose between the helm
and the Shadow Drive.
Install the Shadow Drive between the pump and
the helm.
Do not install the Shadow Drive directly to the
helm.
Do not install the Shadow Drive between the
pump and the cylinder.
Notice
GHP 10 Marine Autopilot System Installation Instructions