Fujitsu 24CL1 Manual - Página 45

Navegue en línea o descargue pdf Manual para Aire acondicionado Fujitsu 24CL1. Fujitsu 24CL1 48 páginas. Mini-split air conditioners and heat pumps

Fujitsu 24CL1 Manual
Compact Ducts
Receiver Unit
UTY-LRHUM
Includes a wireless remote
control.
AOU36RLXFZ
18+18 Combo
Fittings Kit
K9FZ1818
Allows two 18,000 BTU indoor
units to be used on an outdoor
AOU36RLXFZ. Requires special
piping; limited to only 18,000 BTU
models. Total BTU capacity
is limited to 31,600 BTU in
cooling. The kit upsizes linesets
to 3/8" and 1/2".
All Models
3-Pole Single Throw Safety Switch
K3PST
For use where code requires a disconnect at the
indoor unit.
Compatibility
UTY-RNBYU
Wired Remote Control
UTY-RNNUM
Wired Remote Control
Wired Remote Control
UTY-RVNUM
(Backlit, shows room temp.)
UTY-RSNUM
Simple Remote Control
UTY-LNHUM
Wireless Remote Control
UTY-DMMUM
Central Remote Control
UTY-XWZX
Dry Contact Wire Kit
UTY-XWZXZ5
Dry Contact Wire Kit
UTY-XCBXZ1
Interface Kit
UTY-TWBXF
Interface Kit
UTR-DPB24T
Condensate Pump
KHRS940-25
Fresh Air Intake
UTZ-KXGC High Humidity Insulation Kit
UTZ-VXAA
Fresh Air Intake Kit
UTR-YDZB
Air Outlet Shutter Plate
UTY-LRHUM
Receiver Unit
UTY-XSZX
Remote Sensor
UTD-ECS5A Compact Duct Connector Ki t
18+18 Combo Fittings Kit
K9FZ1818
for AOU36RLXFZ
UTY-XWZXZ3
Outdoor Unit Input/Output Connector
UTY-XWZXZ4
Outdoor Unit Base Heater Connector
3-Pole Single Throw
K3PST
Safety Switch
K9R410A55
R410A Swivel Adapter
1 If using UTY-RNBYU with these models you need to change the dip switch SW-1 to "ON". Refer to Tech Tip #028.
2 Wall mounted ASU7, 9, and 12RLF require accessory interface kit #UTY-XCBXZ1 in order to connect these devices to them.
3 Wall mounted ASU9, 12, and 15RLS2 require accessory interface kit #UTY-TWBXF in order to connect these devices to them.
Remote Sensor
UTY-XSZX
Wall mounted temperature
sensor for compact duct
models.
AOU48RLXFZ1
Central 
Remote
Controller
UTY-DMMUM
This remote controls up to 8
individual indoor units. Set
temperatures on timers to
best meet individuals'
needs. Includes a large
backlit LCD and 4-way
navigation pad. Remote
connects in daisy chain to
branch boxes.
Single Zone Wall Mounted
l
l
l
l l
l
l
l
2
3
3
3
3
3
l l l
l l l l l
l
l
l
l l
l
l
l
2
3
3
3
3
3
l
l
2
2
l
l
l
l
l
l
3
3
3
3
3
l
l
2
l l
l l l l
3
l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l
l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l
Simple Remote
Controller
UTY-RSNUM
Suitable when only basic
operations are required for
hotels, offices and other places
where there is frequent arrival
and departure of occupants.
Outdoor Unit
Input/Output
Connector
UTY-XWZXZ3
Gives the ability to limit the noise
of the unit*, stop the outdoor
unit, limit power consumption*,
control the operating mode
(Htg/Clg), or use output status to
see if the compressor is running.
You will need to order a
kit for each option.
*Will reduce capacity.
R410A Swivel Adapter
K9R410A55
In order to minimize incorrect charging of systems with
R22 Fujitsu uses a different access port.  Contractors will
need this 55-degree swivel access fitting.
Single
Single
Zone
Zone
Ducted
Cassette
l
l
l
l
l
1
1
1
1
1
l
l
3
l
l
l l l l l l
l
l
l l l l l l
3
l l l
l l l l l l
l l l
3
l l l
l l l
l l l
l l l
l l l
l l l
Compact Duct
Connector Kit
UTD-ECS5A
Comes with 5 sets of wires. Can
be used to turn unit on/off, wire
in float switch, AUX heater, turn
on an external device (Fan), or
show if the unit is running.
Outdoor Unit
Base Heater
Connector
UTY-XWZXZ4
Used to hook up an AUX base pan
heater to the outdoor unit. Heater
will stop ice from forming in the out-
door unit. Base heater will operate
when outdoor temperature is below
36°F. Heater is field supply. Heaters
greater than 25W can't be fed
directly from the board, but have to
be powered from another source.
Universal/
Large
HFI Multi-Zone
Ceiling
Cassette
and Flex-Zone
Suspended
l
l
l
1
1
1
l
l
l
2
3
l
l
l l l
2
3
l
l l
2
l
3
l
l
l
l l l l
l
l
l
l l l
l
l
l l l
l
l
l
l
l
l
l
l
l
l
45