ERROR CONTENTS

The OPERATION, TIMER and SWING lamps operate
as follows according to the error contents.
Indoor unit circuit board error
Indoor unit room temperature sensor wire opened
Indoor unit room temperature sensor wire short circuited
Indoor unit piping sensor wire opened
Indoor unit piping sensor short circuited
Outdoor unit
Indoor unit
Indoor unit fan error
Outdoor unit heat exchanger temperature sensor error
Outdoor unit outdoor temperature sensor error
Outdoor unit discharge temperature sensor error
Outdoor unit compressor temperature sensor error
Outdoor unit pressure switch error
Outdoor unit 2 way valve temperature sensor error
Outdoor unit 3 way valve temperature sensor error
Indoor unit fan connection capacity error
IPM error
Compressor loter location error
Outdoor fan motor error
:
Fast flashing
2005.07.14
Error contents
Indoor unit communication error
Outdoor unit communication error
:
Slow flashing
Error display
OPERATION
(RED)
2 times
2 times
3 times
3 times
5 times
5 times
6 times
:
Off
9
TIMER
SWING
(GREEN)
(ORANGE)
3 times
4 times
5 times
8 times
9 times
2 times
3 times
4 times
10 times
13 times
14 times