AEG 21602G-B Instrucciones de uso e instalación - Página 11
Navegue en línea o descargue pdf Instrucciones de uso e instalación para Placa AEG 21602G-B. AEG 21602G-B 27 páginas.
Instructions for the Installer
Engineer technical data
OVERALL DIMENSIONS
CUT OUT DIMENSIONS
SUPPLY CONNECTIONS
IGNITION HT SPARK Spark Generator
HEAT INPUT
Rear Left Burner
(semi rapid)
Front Left Burner
(rapid)
Rear Right Burner
(semi rapid)
Front Right Burner
(auxiliary)
APPLIANCE CLASS
APPLIANCE CATEGORY
GAS SUPPLY
Width: 580 mm.
Depth: 500 mm.
Width: 550 mm.
Depth: 470 mm.
Gas:
R 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp cartridge fuse.
Ispra Control's BF 80066 - 220-240V 0.6 VA T120
Spark Gap : Fixed
2.0 kW (6824 BTU/HR)
3.0 kW Natural Gas (10236 BTU/HR)
2.8 kW L.P.G. (9554 BTU/HR)
2.0 kW (6824 BTU/HR)
1.0 kW (3412 BTU/HR)
3
II2H3+
Natural gas G20 / 20mbar
45