4.1.3 Codes & Regulations
This product is designed and manufactured to comply with national codes. It is
installer's responsibilities to install the product in accordance with such codes and/or
any prevailing local codes/regulations. The manufacturer assumes no responsibilities
for equipment installed in violation of any codes or regulations.
These instructions are intended as a general guide and do not supersede local or
national codes in any way. Authorities who have jurisdiction should be consulted before
installation.
4.1.4 Replacement Parts
When reporting shortages or damages, or ordering repair parts, give the complete
product model and serial numbers as stamped on the product. Replacement parts for
this product are available through your contractor or local distributor.

4.2 Location

outdoors.
When installing the coil, take consideration to minimize the length of refrigerant
tubing as much as possible. Do not install the air handler in a location either above or
below the condenser that violates the instructions provided with the condenser. Service
clearance is to take precedence. Allow a minimum of 24" in front of the unit for service
clearance. When installing in an area directly over a finished ceiling (such as an attic),
an emergency drain pan is required directly under the unit. See local and state codes
for requirements. When installing this unit in an area that may become wet, elevate the
unit with a sturdy, non-porous material. In installations that may lead to physical
damage (i.e. a garage) it is advised to install a protective barrier to prevent such
damage.

4.3 Piping Work

4.3.1 Specification of Connection Pipe
Model
ACAT24F/NaA
ACAT48H/NaA
This coil is designed for indoor installation only. Do not install it
ACAT36F/NaA
ACAT60H/NaA
External diameter (inch)
Gas pipe
Φ3/4
5
A-Coils
Liquid pipe
Φ3/8