Fujitsu RSG14KETA-B Instrucción de servicio - Página 8
Navegue en línea o descargue pdf Instrucción de servicio para Aire acondicionado Fujitsu RSG14KETA-B. Fujitsu RSG14KETA-B 47 páginas. Split type room air conditioner, compact cassette / slim duct / mini duct / wall mounted inverter multi
![Fujitsu RSG14KETA-B Instrucción de servicio](/uploads/products/server2/2411239/2411239.png)
Trouble shooting 5
OUTDOOR UNIT Error Method:
Indoor unit capacity error
Detective Actuators:
All indoor units
Forecast of Cause :
1. The selection of indoor units is incorrect
Check Point 1 : Check the total capacity of indoor unit
Check the total capacity of the connected indoor units.
>> If abnormal condition is found, correct it by referring
to Installation Manual or Design & Technical Manual.
OK
OK
Check Point 2 : Replace Main PCB
If Check Point 1 do not improve the symptom, replace Main PCB of Outdoor unit.
Indicate or Display:
Error code : 22
Detective details:
The total capacity of the indoor units if it is install beyond.
2. Main PCB(Outdoor unit) failure
02-06
Outdoor unit : No indication